Fisher & Paykel 517735 service manual

Models: 517735

1 92
Download 92 pages 53.84 Kb
Page 70
Image 70

14.Lay the cabinet on its back, on protective material, and slide the outer bowl assembly out, but note that approximately 1 litre of water must be removed from the pump sump before laying the cabinet on its back.

15. To remove the pump, release the locking tab. Turn the pump anti-clockwise, lift it clear and remove the electrical connections.

16. Remove the two screws securing the wiring duct to the outer bowl base.

17. Remove the drain hose clamp. Twist the drain hose in an anti-clockwise direction to release the bayonet fitting. If changing the outer bowl, the pump securing plate can be removed at this stage by unscrewing the 4 x 3/8" securing bolts.

18. Remove the clamp from the pressure tube and pull the tube off the spigot on the pressure chamber.

19. Unclip the pump harness and then remove the complete assembly.

- 65 -

Page 70
Image 70
Fisher & Paykel 517735 service manual