2.0 SPECIFICATIONS

Dimensions

 

Compact (5kg)

 

Medium (6kg)

 

Large(7kg)

Height to closed Lid

900mm-930mm

 

900mm-930mm

 

900mm-930mm

Height to open Lid

1280m-1310mm

 

1305mm-1335mm

 

1350mm-1380mm

Width

560mm

 

600mm

 

 

650mm

Depth

560mm

 

600mm

 

 

650mm

Inlet hose length

1100mm

 

1100mm

 

 

1100mm

Dry weight Packed

48Kg

 

52Kg

 

 

58Kg

Dry weight unpacked

43Kg

 

46Kg

 

 

51Kg

Wash Load AS2040

5.0-5.5Kg

 

6.0-6.5Kg

 

 

7.0-7.5Kg

High Water Capacity

63-68L

 

76-82L

 

 

89-94L

Finish

 

 

 

 

 

 

Cabinet

 

Prepaint (Polyester)

 

Inner Bowl

 

Stainless Steel grade 430T

 

Lid, Console, Outer Bowl, Agitator

Polypropylene

 

 

 

Touch Panel

 

Polycarbonate

 

 

 

Water fill temp (Default settings)

60oC

 

 

 

Hot

 

Cold as per

supply temperature.

Hot / Warm

 

50oC

Inlet hot water temperature is best

Warm

 

40oC

at 65oC and

should not exceed

Warm / Cold

 

35oC

75oC.

 

Motor. See Section 4.2 for specifications on the stator and rotor.

Pump. See Section 4.7 for specifications.

Water Valves. See Section 4.5 for specifications.

Inlet Water Flow Rate

3 litres per minute minimum.

Standpipe height from floor

Min 850mm Max 1200mm.

Thermistor

Phase 5. NTC-type temperature sensor Resistance 10k ohms @ 25oC. 12.5k ohms @ 20oC In Phase 1-4 this part is not serviceable and mounted within the Motor Controller.

Inner Bowl Speed

 

Fast Spin

1,000 RPM

Medium Spin

700 RPM

Slow

300 RPM

Stir Speed

25 RPM

Fabric Softener Dosage

75cc

Electric Supply

220/240V AC 50Hz

Max Current

2.8 amps

Acceptable weights for the Inner Bowl

Small (5kg)

10.9-11.5kg

Medium (6kg)

8.9-9.4kg

Compact (7kg)

7.0-7.5kg

CAUTION

ALL TERMINALS AND INTERNAL PARTS SHOULD BE TREATED AS LIVE.