Fisher & Paykel 517735 Levelling Smartdrive, Finally, LOW Inlet Water Pressure, Draining, Safety

Models: 517735

1 92
Download 92 pages 53.84 Kb
Page 10
Image 10

LEVELLING SMARTDRIVE

It is IMPORTANT to level Smartdrive to ensure even spin performance. Fit the 4 rubber inserts into the feet on the base of Smartdrive.

Move Smartdrive to its final position. (a minimum clearance of 20mm each side of Smartdrive for ease of installation.)

Adjust the feet so that Smartdrive is level and cannot rock.

To check if Smartdrive is level

look into Smartdrive bowl and make sure it

sits slightly forward of centre.

FINALLY

Turn on the water and check all hose connections for leaks. Make sure there are no kinks in the hoses.

Uncoil power cord and plug into wall socket. If using an extension cord ensure that it is positioned so that it does not come into contact with water or moisture.

INSTALLATION ENVIRONMENT

WATER SUPPLY TEMPERATURES

For best operation the hot water should be approximately 65ºC. The cold water should not exceed 35ºC or the hot water should not exceed 75ºC. Temperatures above this may cause a fault or cause damage to Smartdrive. If there is an uncontrolled water heating source (e.g. a wet back or solar heating system) fit a Hot ‘n’ Safe Valve. This will ensure the hot water temperature remains within safe limits.

Hot ‘n’ Safe Valves available are:- RMC TVA 75HF (3/4 inch pipe) RMC TVA 50HF (1/2 inch pipe) Adjustable between 35ºC - 65ºC RMC TVA 50HP (1/2 inch pipe)

For instantaneous gas hot water supply.

LOW INLET WATER PRESSURE

A slow flow rate (less than 5 litres per minute) into Smartdrive will be improved by fitting large bore inlet hoses p.n.426123.

DRAINING

Check that the standpipe or tub are free from lint and other obstructions.

Draining must comply with local by-laws.

SAFETY

Smartdrive is not intended for use by young children or infirm persons without supervision. Never reach into Smartdrive if the wash bowl or agitator is moving. Press START/ PAUSE and wait until Smartdrive has completely stopped before opening the lid.

ACCESSORIES AND SPARE PARTS

 

Inlet Valve Cap. Used when no hot water inlet hose connected.

Part No. 388491

Hose Inlet Long (2m)

Part No. 422680

Hose Inlet Large Bore - For water low pressure

Part No. 426123

Drain Hose Extension (1.1m)

Part No. 425627p

- 5 -

Page 10
Image 10
Fisher & Paykel 517735 Levelling Smartdrive, Finally, Installation Environment Water Supply Temperatures, Draining, Safety