136.(10001000) Phase 1 to 5 - Motor Stall

The Motor Controller has been unable to start the motor rotating and signals the Display module with motor stall error. Possible causes of this fault are: Faulty motor harness, faulty or jammed motor, seized bearings or seals, faulty Motor Controller, faulty Rotor Position Sensor or harness.

Primary Source - Wiring

Action - Measure/check the motor harness, connectors and motor for discontinuity. Take a resistance measurement between phases of the motor harness at the Motor Controller. Check that the three stator wires are connected correctly.

Secondary Source - Motor Action

1.Check free rotation of the agitator and bowl by rotating by hand. Bearings and seals may be seized.

2.Check the stator resistances. Check that the star point is located correctly.

3.Check the Rotor Position Sensor and associated harness for water, mechanical damage and corrosion.

Tertiary Source - Motor Controller

Action - If the primary and secondary checks pass inspection then replace the Motor Controller.

144.(10010000) Phase 1 - Motor Controller Software Trap The Motor Controller has developed a fault.

Primary Source - Motor Controller

Action

1.Power off for 5 seconds & try again

2.Check connections between the Display Module & the Motor Controller

3.Replace Motor Controller

- 59 -

Page 64
Image 64
Fisher & Paykel 517735 service manual Phase 1 to 5 Motor Stall