32.(00100000) Phase 1 - Pump Circuit Error

The Display Module has detected that the pump is on when it is off.

Primary Source - Display Module

Action

1.Check for moisture in the console area.

2.Replace the Display Module.

33.(00100001) Phase 1 - Water Valve Fault The Module has detected a water valve fault.

Primary Source - Water Valve connection

Action - Check that both valves are connected up properly.

Secondary Source - Water Valve coil faulty

Action

1.Check the valve coils are not open circuit.

2.Replace Display Module if valve coils are not faulty.

34.(00100010) Phase 1 - Brake Resistor Fault

The circuit that controls the braking of the motor is faulty.

Primary Source - Motor Controller Action - Replace the Motor Controller

Secondary Source - Display Module Action - Replace the Display Module.

If the Display Module corrects the fault, then re-fit the original Motor Controller.

35.(00100011) Phase 1 - MC Reset Error

The Display Module has sent a false signal to the Motor Controller.

Primary Source - 12 way Harness Connection.

Action - Check the 12 way harness connection between the Display Module and the Motor Controller.

Secondary Source - Display Module Action - Replace the Display Module.