Fisher & Paykel 517735 Phase 1 to 5 Bowl Engaged During Agitate, Primary Source Mechanical Action

Models: 517735

1 92
Download 92 pages 53.84 Kb
Page 65
Image 65

160.(10100000) Phase 1 to 5 - Bowl Engaged During Agitate

The bowl has re-engaged itself during agitate. Possible causes for this are a leak in the air bell, bowl is over-loaded with clothes, the clutch has jammed or is fouled with a foreign object.

Primary Source - Mechanical

Action

1.Make sure the bowl is not overloaded with too many clothes.

2.Check that the rotating bowl assembly is not jammed to the agitator with any foreign object that may be caught under the agitator skirt.

3.Check that the clutch teeth are not locked together with dirt, lint, etc.

4.If none of the above appear to be at fault, then check the air bell at the bottom of the inner bowl for leaks.

Secondary Source - Motor Controller (Phase 1 to 4 Only).

Action - If Smartdrive is empty of water when faulting it is possible that the pump circuit is faulty and has caused a pump out during wash. This would cause the bowl to re-engage during agitate and the Motor Controller to display this fault. Replace Motor Controller.

161.(10100001) Phase 2 to 5 – Motor Controller Fault

The Motor Controller checks the voltage configuration (i.e. 110v or 230V) against its EEPROM on power up. Should there be a mismatch, this error is flagged.

Primary Source - Motor Controller Action - Replace Motor Controller.

162.(10100010) Phase 3 to 5 Brake Deceleration Time-out Fault

During the brake mode the Motor Controller has detected that the bowl has not come to a stop in the permitted time once dropping below 100 RPM. This fault has been installed for software testing only.

163.(10100011) Phase 4 to 5 - Motor Controller Fault

The Motor Controller has internally sensed a connection is open circuit. The cold valve cannot be operated with this condition.

Primary Source - Motor Controller. Action - Replace Motor Controller.