Table B-4. Available Display Lines

 

 

 

 

 

 

 

 

 

 

 

Display Line

 

 

 

 

 

 

 

 

 

 

Group

Title

 

Appearance

 

 

(on the Rotating Rack)

(on the Rotating Rack)

(on a Measurement Display)

 

 

Configuration

Blank Line

 

 

 

 

 

 

 

 

 

 

Air Density Setting

ADCF = -.---

 

 

 

 

 

 

 

 

Temperature Pressure

--.- C ---- hPa

 

 

 

 

 

 

 

 

Bias Setting

Set: >+---.- V +---%

 

 

 

 

 

 

 

 

 

Firmware Revision

FW Rev:

15OCT92 A

 

 

 

 

 

 

 

 

 

Time Interval Setting

Interval:

---- s

 

 

 

 

 

 

 

 

IC Calibration Factor

ICCF=1.234E+08 R/C

 

 

 

 

 

 

 

 

Optional Text 1

Optional Text Line 1

 

 

 

 

 

 

 

 

Optional Text 2

Optional Text Line 2

 

 

 

 

 

 

 

Amps, Coulombs, Volts

Battery Voltage

Batt: -.- V +-.—A

 

 

 

 

 

 

 

 

Leakage Current

Leakage: -.--- pA

 

 

 

 

 

 

 

 

Bias Voltage

IC Bias: ---.- V CEP

 

 

 

 

 

 

 

 

 

Charge

--.--- nC

 

 

 

 

 

 

 

 

 

 

Current

---.- pA

 

 

 

 

 

 

 

 

 

Accumulated Charge

--.--- nC ACCUM

 

 

 

 

 

 

 

 

 

Average Current

---.— pA

AVG

 

 

 

 

 

 

 

 

 

Timed Charge

--.--- nC

---- s

 

 

 

 

 

 

 

 

Predicted Timed Charge

--.--- nC PREDICT

 

 

 

 

 

 

 

Dose, Rate

Leakage Rate

Leak: -.--- R/s

 

 

 

 

 

 

 

 

 

Dose

--.--- nR

 

 

 

 

 

 

 

 

 

 

Rate

---.- pR/s

 

 

 

 

 

 

 

 

 

Accumulated Dose

--.--- nR ACCUM

 

 

 

 

 

 

 

 

Average Rate

---.- pR/min AVG

 

 

 

 

 

 

 

 

 

Timed Dose

--.--- nR

---- s

 

 

 

 

 

 

 

 

Predicted Timed Dose

--.--- nR PREDICT

 

 

 

 

 

 

 

 

Time

Time Interval Setting

Interval:

---- s

 

 

 

 

 

 

 

 

 

Timed Charge

--.--- nC

---- s

 

 

 

 

 

 

 

 

Predicted Time Chrg

--.--- nC PREDICT

 

 

 

 

 

 

 

 

 

Timed Dose

--.--- nR

---- s

 

 

 

 

 

 

 

 

Predicted Timed Dose

--.--- nR PREDICT

 

 

 

 

 

 

 

 

 

Effective Exp. Time

--.-- s

 

 

 

 

 

 

 

 

 

Timer Intervals

The Model 35040 Therapy Dosimeter can contain up to twenty (20) timer interval settings, which interval settings, general editing information, and OK and CANCEL buttons.