RIP Configure Commands

configure router rip timers holddown

This command configures the global RIP hold down timers.

Hold down time is the interval in seconds during which routing information regarding better routes is suppressed. This should be configured to be at least twice the value of the update timers.

Parameter

Description

time

Holddown timer value in seconds

 

The range is 1- 65535; the default is 180.

 

 

syntax:

[ no ] holddown time < n >

example:

Foundry-140/configure/router/rip/timers# holddown 200

This example configures the global RIP hold down timers to suppress information about routes for 200 seconds.

related commands:

configure router rip timers flush

configure router rip timers update

applicable systems:

All models.