configure router rip timers flush

This command configures the global RIP flush timer.

This is the time interval in seconds that must pass before the route is removed from the routing table. This value should be configured to be greater than the configured holddown time value.

Parameter

Description

time

Flush timer value in seconds

 

The range is 1 - 65535; the default is 180.

 

 

syntax:

[ no ] flush time < n >

example:

Foundry-AR1208/configure/router/rip/timers# flush 300

This example configures the global RIP flush timer to 300 seconds.

related commands:

configure router rip timers holddown

configure router rip timers update

applicable systems:

All models.