(1)NOx after O2 correction CO after O2 correction

(a)Calculating equation

C=

21 - On

Cs

21- OS

C:Concentration after O2 conversion Cs: NOX or CO concentration measured Os: O2 concentration measured

On: O2 concentration as conversion basic: 4% Oil combustion boiler

5% Gas combustion boiler

6% Solid object combustion boiler, petroleum heating furnace

12% Garbage incinerator

(b)Block diagram

Zurconia

type O2 sensor

 

NOx or

 

 

CO signal

 

 

21 - On

· Cs

 

21 - Os

O2

O2

 

converter

signal

 

O2/NOx conversion or CO (ppm)

Full scale is the same as instantaneous value before conversion.

Infrared gas analyzer

(2)Moving average output

1 hr. moving average output (for NOx, SO2) 4 hr. moving average output (for CO)

– 47 –

Page 55
Image 55
Fuji Labs ZSP instruction manual Block diagram, Moving average output