Chapter 9 Messages
9.1 Event Log Messages
ETERNUS VSS Hardware Provider 2.1 User’s Guide
Copyright 2012 FUJITSU LIMITED P3AM-4582-03ENZ0
93
Event ID: 2102
Type:Error
Messages:STXV2102 ERROR The IP address cannot be found.
Details:
The IP address cannot be found. The process is canceled.
Execute the Communication Environment Setup function to set the IP address, and try again.
To start the Communication Environment Setup function, click the [Start] button – [All Programs] –
[ETERNUS VSS Hardware Provider] – [Communication Environment Setup].
[For a Server Core environment]
Execute the "Communication Environment Setup Command".
For details, refer to "8.8 Communication Environment Setup Command (stxvsetcommu)" (page 64).
Event ID: 2103
Type:Error
Messages:STXV2103 ERROR The port number cannot be found.
Details:
The port number cannot be found. The process is canceled.
Check that the port number is correctly specified in the registry, and try again.
Event ID: 2104
Type:Error
Messages:STXV2104 ERROR The timeout value cannot be found.
Details:
The timeout value cannot be found. The process is canceled.
Check that the timeout value is correctly specified in the registry (or the VSSHP environment file),
and try again. The process continues with the timeout value set to "60 seconds".
Event ID: 2105
Type:Error
Messages:STXV2105 ERROR An error occurred in the backup server.
Details:
An error occurred in the backup server. The process is canceled.
Check the event logs of the backup sever, and take action according to the output error message.