Fujitsu AOU12RL2 Heating Operation, COOL AIR PREVENTION CONTROL Heating mode, Normal operation

Models: ASU12RL2 AOU09RL2 AOU12RL2

1 62
Download 62 pages 59.61 Kb
Page 10
Image 10
5. HEATING OPERATION

5. HEATING OPERATION

Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature, as shown in Fig. 5 On the other hand, if switched in [Hi] [Quiet], the indoor motor will run at a constant airflow

of [Heat] operation modes Quiet, Lo, Me, High, as shown in Table 6. ( Fig.5 : Airflow change - over ( Heating : Auto ) )

When the room

 

When the room

TR : Room temperature

temperature rises

 

 

temperature drops

Ts : Setting temperature

 

 

 

 

 

TR-Ts > -1°C (-2°F)

 

Lo mode

 

 

 

 

 

 

 

 

 

=

 

 

 

 

TR-Ts > -1.5°C (-3°F)

 

 

 

 

 

 

 

 

 

 

 

=

 

-1°C (-2°F)> TR-Ts > -2°C (-4°F)

 

 

 

 

 

 

 

 

 

 

 

=

 

 

 

Me mode

 

-1.5°C (3°F) > TR-Ts > -2.5°C (-5°F)

 

 

 

 

 

 

=

-2°C (-4°F)> TR-Ts

 

 

 

 

 

 

 

 

Me+ mode

 

-2.5°C (-5°F)> TR-Ts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. COOL AIR PREVENTION CONTROL (Heating mode)

The maximum value of the indoor fan speed is set as shown in Fig.6 based on the detected temperature by the indoor heat-exchanger sensor on heating mode.

( Fig.6 : Cool air prevension control )

 

<Normal operation>

<Powerful operation>

When the Indoor heat

When the Indoor heat

When the Indoor heat

exchanger temp. rises

exchanger temp. drops

exchanger temp. rises

When the Indoor heat

exchanger temp. drops

42°C (108°F)

39°C (102°F)

37°C (99°F)

30°C (86°F)

*Hi or setting Fan mode

*Me+ or setting Fan mode

*Lo or setting Fan mode

Cool air prevention

S-Lo

 

42°C

 

 

 

 

 

37°C (99°F)

(108°F)

39°C

 

 

 

 

 

(102°F)

34°C (93°F)

37°C

 

 

 

 

(99°F)

 

30°C

 

 

 

32°C (90°F)

(86°F)

 

28°C (82°F)

 

Powerful

 

 

 

 

Hi

 

 

 

37°C

 

 

 

 

 

 

 

(99°F)

Lo

 

 

 

 

34°C

 

 

 

Cool air

 

 

 

 

(93°F)

 

 

 

 

32°C

 

 

 

prevention

 

 

 

(90°F)

 

 

 

 

 

S-Lo

 

 

 

28°C

 

 

 

 

 

 

 

 

(82°F)

* Lower speed is selected.

*Lower speed is selected.

7.MOISTURE RETURN PREVENTION CONTROL (Cooling mode& Dry mode)

Switch the airflow [Auto] at cooling mode, and the indoor fan motor will run as shown in Fig.7. ( Fig.7 : Indoor fan control )

Compressor

ON 6. COOL AIR PREVENTION CONTROL (Heating mode)( Fig.6 : Cool air prevension control )

OFF

Indoor fan

Setting air flow

Indoor fan

(as shown in Table 7)

S-Lo

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

10

30

60

180

60

180

60

10

30

(sec)

( Table 7 : Indoor fan speed )

 

 

Dry

 

Cooling

 

 

 

 

 

X zone

J zone

Y zone

 

 

 

 

 

 

 

ASU09/12RL2

700rpm

600rpm

0 480rpm

700rpm

 

 

 

 

 

01-05

Page 10
Image 10
Fujitsu AOU12RL2, ASU12RL2 manual Heating Operation, COOL AIR PREVENTION CONTROL Heating mode, Cool air prevension control