Trouble shooting 20

Outdoor Unit - No Power

Forecast of Cause:

1.

Power supply failure 2. External cause

3.

Electrical Components defective

Check Point 1 : Check Installation Condition

Isn’t the breaker down?

Check loose or removed connection cable.

>>If abnormal condition is found, correct it by referring to Installation Manual or Data & Technical Manual.

OK

Check Point 2 : Check external cause at Indoor and Outdoor (Voltage drop or Noise)

Instant drop -----

Check if there is a large load electric apparatus in the same circuit.

Momentary power failure -----

Check if there is a defective contact or leak current in the power supply circuit.

Noise -----

Check if there is any equipment causing harmonic wave near electric line.

 

(Neon bulb or electric equipment that may cause harmonic wave)

 

Check the complete insulation of grounding.

OK

Check Point 3 : Check Electrical Components

Check the voltage of power supply.

NO

 

>>Check if AC103 - 127V appears at Outdoor Unit Terminal L - N.

YES

Check Fuse in Main PCB.

>>If Fuse is open, check if the wiring between Terminal and Main PCB is loose, and replace Fuse.

Check Varistor in Main PCB.

>>If Varistor is defective, there is a possibility of an abnormal power supply. Check the correct power supply and replace Varistor.

Upon checking the normal power supply, replace Varistor.

OK

If the symptom does not change by above Check 3, replace Main PCB.

02-22

Page 45
Image 45
Fujitsu ASU12RL2, AOU12RL2, AOU09RL2 manual Outdoor Unit No Power