5. INDOOR FAN CONTROL

1. Fan speed

( Table 6 : Indoor fan speed )

Operation mode

Air flow mode

Speed (rpm)

ASU09RL2

ASU12RL2

 

 

 

 

 

 

Heating

Powerful

1420

1420

 

Hi

1360

1360

 

Me+

1290

1290

 

Me

1120

1120

 

Lo

900

900

 

Quiet

700

700

 

Cool air prevention

600

600

 

S-Lo

480

480

Cooling/ Fan

Powerful

1400

1400

 

Hi

1320

1320

 

Me

1120

1120

 

Lo

840

860

 

Quiet

700

700

 

* Soft Quiet

600

600

Dry

 

X zone: 700

X zone: 700

 

 

J zone: 600

J zone: 600

 

 

 

 

*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs. (Hi > Me, Me > Lo, Lo > Quiet, Quiet > Soft Quiet)

2. FAN OPERATION

The airflow can be switched in 5 steps such as Auto, Quiet, Lo, Me, Hi, while the indoor fan only runs. When fan mode is set at [Auto], it operates on [Me] fan Speed.

3. COOLING OPERATION

Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature, as shown in Fig4. On the other hand, if switched in [Hi] [Quiet], the indoor motor will run at a constant airflow of [Cool] operation modes Quiet, Lo, Me, Hi, as shown in Table 6.

( Fig.4 : Airflow change - over ( Cooling : Auto ) )

 

 

 

 

When the room

 

When the room

 

temperature rises

 

 

 

 

 

 

temperature drops

 

 

TR-Ts > 2.5°C (5°F)

TR : Room temperature

TR-Ts > 2°C (4°F)

 

Hi mode

 

 

=

Ts : Setting temperature

 

 

 

2.5°C (5°F) > TR-Ts > 1.5°C (3°F)

 

 

 

 

 

 

 

 

 

2°C (4°F) > TR-Ts > 1°C (2°F)

 

Me mode

 

 

 

=

 

 

 

 

 

=

 

 

 

 

 

 

 

 

 

Lo mode

 

1.5°C (3°F) > TR-Ts

 

 

 

 

 

 

1°C (2°F) > TR-Ts

 

 

 

 

 

 

 

4.DRY OPERATION

Refer to the Table 6.

During the dry mode operation, the fan speed setting can not be changed.