Fujitsu AOU09RL2, ASU12RL2, AOU12RL2 manual Outdoor Fan Control, Outdoor Fan Motor, Fan Speed

Models: ASU12RL2 AOU09RL2 AOU12RL2

1 62
Download 62 pages 59.61 Kb
Page 11
Image 11
6. OUTDOOR FAN CONTROL

6. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor

Following table shows the type of the outdoor fan motor. The control method is different between AC motor and DC motor.

( Table 8 : Type of Motor )

AC motor DC motor

AOU09RL2

AOU12RL2

2. Fan Speed

( Table 9 : Outdoor fan speed )

 

Zone

Cooling

Heating

Dry

 

Y

730 / 650 / 470

 

 

AOU09RL2

Z

730 / 470 / 360

900 / 650 / 470

730 / 470

F

360 / 150

 

 

 

 

G

210 / 150

 

 

 

Y

860 / 760 / 470

 

 

AOU12RL2

Z

860 / 470 / 380

900 / 760 / 680 / 470

760 / 470

F

380 / 280

 

 

 

 

G

280 / 200

 

 

1. Outdoor Fan Motor Refer to Fig.8

( Fig.8 : Outside air temperature zone selection )

Outside air temperature

21°C (70°F)

12°C (54°F)

2°C (36°F)

Yzone

Zzone

Fzone

Gzone

Outside air temperature

19°C (66°F)

10°C (50°F)

0°C (32°F)

*The outdoor fan speed mentioned adove depends on the compressor frequency.

(When the compressor frequency increases, the outdoor fan speed also changes to the higher speed. When the compressor frequency decreases, the outdoor fan speed also changes to the lower speed.)

*After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed as table 10 without relating to the compressor frequency.

( Table 10 : Outdoor fan speed after the defrost )

AOU09RL2

AOU12RL2

900 rpm

01-06

Page 11
Image 11
Fujitsu AOU09RL2, ASU12RL2, AOU12RL2 manual Outdoor Fan Control, Outdoor Fan Motor, Fan Speed