SERVICE PARTS INFORMATION 4

Indoor unit fan motor

Check Point 1 : Check rotation of Fan

Rotate the fan by hand when operation is off. (Check if fan is caught, dropped off or locked motor)

>>If Fan or Bearing is abnormal, replace it.

Check Point 2 : Check resistance of Indoor Fan Motor

Refer to below. Circuit-test "Vm" and "GND" terminal. (Vm: DC voltage, GND: Earth terminal)

>>If they are short-circuited (below 300 k ), replace Indoor fan motor and Controller PCB.

Pin number

Terminal function

(wire color)

(symbol)

 

 

 

1

(Blue)

Feed back (FG)

2

(Yellow)

Speed command (Vsp)

3

(White)

Control voltage (Vcc)

4

(Black)

Earth terminal (GND)

5

 

No function

6

(Red)

DC voltage (Vm)

SERVICE PARTS INFORMATION 5

Outdoor unit fan motor

Check Point 1 : Check rotation of Fan

Rotate the fan by hand when operation is off. (Check if fan is caught, dropped off or locked motor)

>>If Fan or Bearing is abnormal, replace it.

Check Point 2 : Check resistance of Outdoor Fan Motor

Refer to below. Circuit-test "Vm" and "GND" terminal. (Vm: DC voltage, GND: Earth terminal)

>>If they are short-circuited (below 300 k ), replace Outdoor fan motor and Main PCB.

 

Pin number

Terminal function

 

(wire color)

(symbol)

 

 

 

1

(Red)

DC voltage (Vm)

2

 

No function

3

 

No function

4

(Black)

Earth terminal (GND)

5

(White)

Control voltage (Vcc)

6

(Yellow)

Speed command (Vsp)

7

(Brown or Blue)

Feed back (FG)

02-29

Page 52
Image 52
Fujitsu AOU12RL2, ASU12RL2, AOU09RL2 manual Indoor unit fan motor, Outdoor unit fan motor