3-1. FUNCTION SETTING

3-1-1 INDOOR UNIT

Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition.

After the power is turned on, perform the Function Setting on the remote control.

The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected.

1-1. Setting the Filter Sign

The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting for the filter sign display interval in the table

below according to the amount of dust or debris in the room.

If you do not wish the filter sign to be displayed, select the setting value for "No indication".

 

(

Factory setting)

Setting Description

Function Number

Setting Value

Standard (400 hours)

 

00

 

 

 

Long interval (1000 hours)

11

01

 

 

Short interval ( 200 hours)

02

 

 

 

 

No indication

 

03

 

 

 

1-2. Cooling Room Temperature Correction

Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below.

 

(

Factory setting)

 

 

 

Setting Description

Function Number

Setting Value

 

 

 

Standard

 

00

Slightly lower control

30

01

 

 

Lower control

02

 

Warmer control

 

03

 

 

 

1-3. Heating Room Temperature Correction

Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below.

 

(

Factory setting)

 

 

 

Setting Description

Function Number

Setting Value

 

 

 

Standard

 

00

Lower control

31

01

 

 

Slightly warmer control

02

 

 

 

 

Warmer control

 

03

 

 

 