3. SLEEP TIMER

If the sleep is set, the room temperature is monitored and the operation is stopped automatically. If the operation mode or the set temperature is change after the sleep timer is set, the operation is continued according to the changed setting of the sleep timer from that time ON.

In the cooling operation mode

When the sleep timer is set, the setting temperature is increased 1°C (2°F). It increases the setting temperature another 1°C (2°F) after 1 hour.

After that, the setting temperature is not changed and the operation is stopped at the time of timer setting.

Set temperature rises ( Ts : Set temperature )

+2°C (4°F) +1°C (2°F)

Ts

Stop of operation

Set 60min

In the heating operation mode

When the sleep timer is set, the setting temperature is decreased 1°C (2°F). It decreases the setting temperature another 1°C (2°F) every 30 minutes.

Upon lowering 4°C (8°F), the setting temperature is not changed and the operation stops at the time of timer setting.

Set temperature lowers ( Ts : Set temperature )

Ts

-1°C (-2°F)

-2°C (-4°F)

-3°C (-6°F)

-4°C (-8°F)

Stop of operation

Set 30min 30min 30min