Troubleshooting
Service Parts Information
Defrost Flow Chart
Remote controller signal code
Error Display
Timer Opeartion Control
Adjust the RIGHT-LEFT Louvers
Function Setting
Room temperature thermistor
Powerful Operation
Page 54
Image 54
R410A
WALL MOUNTED type
INVERTER
3 . APPENDING DATA
Page 53
Page 55
Page 54
Image 54
Page 53
Page 55
Contents
Service Instruction
Contents
Appending Data
Page
Wall Mounted type
Cooling Operation
Heating Operation
DRY Operation
Auto Changeover Operation
01-03
FAN Operation
Indoor FAN Control
Fan speed
Cooling Operation
Cool AIR Prevention Control Heating mode
Moisture Return Prevention Control Cooling mode& Dry mode
Heating Operation
Outdoor FAN Control
Outdoor Fan Motor
Vertical Louver Control
Adjust the RIGHT-LEFT Louvers
Louver Control
Function Range
Opeartion Frequency Range
Limitation of Compressor Frequency by Outdoor Temperature
Compressor Control
Opeartion Frequency Control AT Normal Start UP
Timer Opeartion Control
Program Timer
Sleep Timer
Cooling operation mode
Heating operation mode
Auto Restart
Prevent to Restart for 3 Minutes 3 Minutes ST
FOUR-WAY Valve Extension Select
24C 75F
Compressor Preheating
Powerful Operation
Forced Cooling Operation Test Operation
Economy Operation
Condition of the Defrost Operation Completion
Defrost Operation Control
Condition of Starting the Defrost Operation
Release Condition
Defrost Flow Chart
Normal defrost Integrating defrost
01-14
OFF Defrost Opeartion Control
Defrost end 01-15
Current Release Control
Discharge GAS Temperature Overrise Prevension Control
Various Protections
01-16
Antifreezing Control Cooling and Dry mode
High Temperature Release Control Heating Mode
Cooling Pressure Overrise Protection
Trouble Shooting
Troubleshooting
Error Display
Trouble Shooting with Error Code
Check Point 4 Check Serial Signal Reverse Transfer Signal
Outdoor unit Main PCB
Indoor unit Controller PCB Indoor unit Fan motor
Check Point Check external cause such as noise
Indoor unit Controller PCB
Check Point Check Indoor unit electric components
Check Point 3 Replace Controller PCB
Indoor unit Controller PCB Indicator PCB Manual auto switch
Check Point 2 Replace Controller PCB
Indoor unit Controller PCB Room temperature thermistor
Indoor unit Controller PCB Heat Ex. temperature thermistor
Check Point 2 Check ambient temp. around motor
Check Point 3 Check Indoor unit fan motor
Check Point 2 Replace Main PCB
Check Point 1-2 Check external cause
Check Point 2 Check connection of Connector
Check Point 3 Replace Main PCB
02-11
Outdoor unit Main PCB Discharge pipe temperature thermistor
CN71 CN70
Outdoor unit Main PCB Heat exchanger temperature thermistor
Resistance Value k 606 759 213 8531
Outdoor unit Main PCB Outdoor temperature thermistor
Check Point 4 Replace Main PCB
Outdoor unit Main PCB Compressor
Check Point 2 Check Heat exchanger
Check Point 3 Check Compressor
Check Point 3 Replace Main PCB
Outdoor unit Main PCB Outdoor unit Fan motor
Check Point 3 Check Outdoor unit fan motor
Check Point 4 Check Output Voltage of Main PCB
Check Point 2 Check each thermistor
Check Point 3 Check the solenoid coil and 4-way valve
Forecast of Cause
Trouble Shooting with no Error Code
Indoor Unit No Power
Check Point 3 Check Electrical Components
Outdoor Unit No Power
02-23
Check Point 2 Check Outdoor unit operation
Check Point Check Indoor/ Outdoor installation condition
No Cooling / No Heating
Check Point 3 Check Site condition
Abnormal Noise
Water Leaking
Service Parts Information
Compressor
Replace Compressor
Inverter Compressor
Outdoor unit Electronic Expansion Valve EEV
Blue Red
Check Point 5 Check Opening and Closing Operation of Valve
Indoor unit fan motor
Outdoor unit fan motor
Page
Appending Data
Cooling Room Temperature Correction
Function Setting
Setting the Filter Sign
Heating Room Temperature Correction
Setting the Auto Restart
Remote controller signal code
Yes
Procedures to change the Function Setting for wireless RC
Selecting the Function Number and Setting Value
Remote Controller Signal Code Setting
Room temperature thermistor
Discharge thermistor
Page