Fujitsu AOU12RL2 manual Trouble shooting 6 INDOOR UNIT Error Method, Indoor unit fan motor error

Models: ASU12RL2 AOU09RL2 AOU12RL2

1 62
Download 62 pages 59.61 Kb
Page 31
Image 31
Trouble shooting 6 INDOOR UNIT Error Method:

Trouble shooting 6 INDOOR UNIT Error Method:

Indoor unit fan motor error

Indicate or Display:

Refer to error code table.

Detective Actuators:

Indoor unit Controller PCB Indoor unit Fan motor

Detective details:

When the condition that actual frequency of Indoor Fan is

below 1/3 of target frequency is continued more than 56 seconds.

Forecast of Cause:

 

1.

Fan rotation failure

2. Fan motor winding open 3. Motor protection by surrounding temperature rise

4.

Control PCB failure

5. Indoor unit fan motor failure

 

 

 

Check Point 1 : Check rotation of Fan

Indoor unit fan motor error Rotate the fan by hand when operation is off. (Check if fan is caught, dropped off or locked motor)

>>If Fan or Bearing is abnormal, replace it.

OK

Check Point 2 : Check ambient temp. around motor

Check Point 4 : Replace Controller PCB Check excessively high temperature around the motor. (If there is any surrounding equipment that causes heat)

>>Upon the temperature coming down, restart operation.

OK

Check Point 3 : Check Indoor unit fan motor

Manual background Check Indoor unit fan motor. (PARTS INFORMATION 4)

>>If Indoor unit fan motor is abnormal, replace Indoor unit fan motor.

OK

Check Point 4 : Replace Controller PCB

If Check Point 1- 3 do not improve the symptom, replace Controller PCB.

02-08

Page 31
Image 31
Fujitsu AOU12RL2, ASU12RL2 Trouble shooting 6 INDOOR UNIT Error Method, Indoor unit fan motor error, Detective Actuators