Trouble shooting 3 INDOOR UNIT Error Method:

Trouble shooting 3 INDOOR UNIT Error Method:

Manual auto switch error

Indicate or Display:

Refer to error code table.

Detective Actuators:

Indoor unit Controller PCB Indicator PCB

Manual auto switch

Detective details:

When the Manual auto switch becomes ON for consecutive 60 or more seconds.

Forecast of Cause :

1. Manual auto switch failure 2.Controller PCB and Indicator PCB failure

Check Point 1 : Check the Manual auto switch

Manual auto switch error Check if Manual auto switch is kept pressed.

Manual background Check ON/OFF switching operation by using a meter.

>>If Manual Auto Switch is disabled (on/off switching), replace it.

Manual background OK

Check Point 2 : Replace Controller PCB

Manual background If Check Point 1 do not improve the symptom, change Controller PCB and Indicator PCB.

02-05

Page 28
Image 28
Fujitsu AOU12RL2, ASU12RL2 manual Trouble shooting 3 INDOOR UNIT Error Method, Manual auto switch error, Detective Actuators