Table 4: ProMix 2KS Modbus/TCP Variable Map

 

EasyKey

 

 

 

 

 

* Read/Write

Modbus

 

 

 

 

 

Status

Register

Description

Size

Units

Low Limit

High Limit

 

 

 

 

 

 

 

Read Only

40003

Current flow rate

16 Bit

cc/min

0

5000

Read Only

40004

Actual ratio

16 Bit

none

0

9999

Read Only

40005

Active recipe

16 Bit

none

0

60

Read Only

40006

Potlife 1 remaining

16 Bit

sec

0

9999

Read/Write

40007

Job complete

16 Bit

none

0

0xFFFF

Read/Write

40008

Reset job total

16 Bit

none

0

9

Read Only

40009

Potlife 2 remaining

16 Bit

sec

0

9999

Read Only

40010

Active fault

32 Bit

none

0

0xffffffff

Read Only

40032

Control version

32 Bit

none

0

0xffffffff

Read/Write

40040

Robot digital input

16 Bit

none

0x0000

0xFFFF

Read Only

40041

Robot digital output

16 Bit

none

0x0000

0xFFFF

Read/Write

40046

New recipe

16 Bit

none

0

60

Read Only

40048

Current fluid pressure

16 Bit

psi

0

5000

Read Only

40049

V/P percent output

16 Bit

%

0

100

Read Only

**40056

Actual ratio reducer

16 Bit

none

0

9999

Read Only

40114

Flow control option

16 Bit

0=proportioning only

0

4

 

 

 

 

1=1K flow control

 

 

 

 

 

 

(future)

 

 

 

 

 

 

2=2K flow control

 

 

 

 

 

 

3=pressure override

 

 

 

 

 

 

4=manual percent

 

 

 

 

 

 

override

 

 

Read/Write

40115

Flow setpoint data source

16 Bit

0=discrete

0

1

 

 

 

 

1=network

 

 

Read/Write

40120

Manual override percent

16 Bit

%

0

100

 

 

opening

 

 

 

 

Read/Write

40125

Flow control range

16 Bit

0=0-300 cc/min

0

2

 

 

 

 

1=0-600 cc/min

 

 

 

 

 

 

2=0-1200 cc/min

 

 

Read/Write

40126

Flow control tolerance

16 Bit

%

0

99

Read/Write

40127

Flow control proportional

16 Bit

default=400

0

9999

 

 

gain Kp

 

 

 

 

Read/Write

40128

Flow control integral gain

16 Bit

default=40

0

9999

 

 

Ki

 

 

 

 

Read/Write

40129

Flow control alarm time

16 Bit

sec

0

99

Read/Write

40137

Flow control setpoint

16 Bit

cc/min

0

1200

Read/Write

43123

Flow control override

16 Bit

0=off (normal)

0

2

 

 

mode

 

1=% open

 

 

 

 

 

 

2=pressure mode

 

 

Read/Write

43141

Flow control enable

16 Bit

0=off

0

1

 

 

 

 

1=on

 

 