Troubleshooting

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

 

Symbol or image leaves a trace when

The background of the image is not

Change the primitive Fill Format to

animated.

refreshed.

Solid color.

 

 

 

 

 

Add the system variable dispcount

 

 

in the background of the image to

 

 

force the refresh.

 

 

 

Rich Bar Graph or Dial Gauge does

Tag minimum and maximum are not

Check the tag’s minimum and maxi-

not move

setup.

mum values. These are used by both

 

 

primitives for minimum and maxi-

 

 

mum.

 

 

 

Trend Viewer curve stuck at the bot-

No minimum and maximum setup on

Check that all displayed tags in the

tom.

the data tags displayed in the viewer.

trend viewer have a Minimum and a

 

 

Maximum setup.

 

 

 

USB Drivers location for Windows.

Location of the drivers unknown.

The drivers are located under Graco

 

 

Gateway 2.0\Device installation

 

 

folder. For example C:\Program

 

 

Files\Graco Gateway\Device.

 

 

 

USB Driver installation.

The operating system is unable to

In your operating system device man-

 

find the driver or the installation

ager, check if the Graco Gateway is

 

failed.

present. If so, uninstall that device.

 

 

Follow the USB installation guide.

 

 

 

Upgrading Graco Gateway did not

The option selected during the

Launch the upgrade again and

upgrade the software version.

upgrade was Modify instead of

choose Repair when prompted.

 

Repair.

 

 

 

 