System Electrical Schematic

System Electrical Schematic

Non-Hazardous Area

NON-HAZARDOUS AREA

POWER HARNESS

 

OPERATOR INTERFACE

 

 

 

DC OK

+

POWER

1

L1 85-250 VAC

 

+24 VDC

+

2

N

 

SUPPLY

 

COMMON

-

 

 

 

 

 

 

 

COMMON

-

 

 

 

 

 

 

 

1

UNUSED

 

 

 

 

2

UNUSED

 

 

 

J1

3

UNUSED

 

 

 

 

4

UNUSED

HARNESS

 

 

 

5

UNUSED

 

 

 

 

L1

 

LINE

L1

 

 

 

 

FILTER

N

 

 

 

N

 

 

 

 

 

 

 

 

GND

L1

TERMINAL

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

N

BLOCK

N

 

 

 

 

 

 

1

GND

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

GND LUG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

GND N L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

85-250

 

 

 

 

 

 

1

POWER

 

 

 

 

 

 

 

 

VAC

 

 

 

 

 

 

2

ROCKER

 

 

 

 

OPEN

1A

SWITCH

 

 

 

 

1B

 

 

 

 

 

OPEN

2A

 

 

 

 

 

2B

 

 

 

MEMBRANE SWITCH WITH RIBBON CABLE

DISPLAY

J4

J2

1

DISPLAY

1

BOARD

2

J9

2

3

 

3

4

 

4

5

RJ45

RJ45

6

 

 

7J6

8

9

10

11

1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

6

 

 

7

 

 

8

 

 

9

 

1

10

 

 

2

11

 

 

3

12

 

 

4

13

 

J5

5

14

15

 

6

 

7

16

 

 

8

17

 

 

9

18

 

 

10

19

 

20

 

 

 

 

1

 

 

2

 

J10

3

 

 

4

 

 

5

 

 

6

 

 

 

J5

1

 

+12VDC I/S (RED)

 

 

 

 

 

 

2

 

COM (BLACK)

 

 

 

 

 

BARRIER

3

 

SHIELD

 

 

 

 

 

BOARD

1

 

+24VDC

 

 

 

 

 

 

J4

 

 

 

 

 

 

 

2

 

OPEN

 

 

 

 

 

 

 

3

 

COMMON

 

 

 

 

 

 

 

 

 

 

ALARM

 

 

 

+

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

3'

 

 

 

 

 

POWER DIST.

 

 

 

RJ45

 

RJ45

 

TERMINAL

 

 

 

 

 

 

 

 

 

BLOCKS

 

 

 

 

 

 

 

 

-

+

 

 

 

 

 

 

 

-

+

 

 

 

 

REMOTE

 

 

 

 

 

 

 

 

-

+

 

 

 

 

I/O

 

 

 

 

 

 

 

 

INTEGRATION

-

+

 

 

 

 

BOARD

 

 

 

 

 

 

SHIELD

 

 

 

FLOW CONTROL CAL. (BLK)

 

 

1

 

 

 

 

GUN TRIGGER (WHT)

 

 

2

 

 

 

 

DIGITAL IN COMMON (RED)

 

 

3

 

 

 

 

REMOTE STOP (GRN)

 

 

4

 

 

 

 

ALARM RESET (BRN)

 

 

5

 

 

 

 

ALARM OUTPUT (BLU)

 

 

6

 

 

 

 

DIGITAL OUTPUT COMMON (ORG)

 

 

7

 

 

 

 

POT LIFE (YEL)

 

 

8

 

 

 

 

FLOW RATE ANALOG IN (PUR)

 

 

9

 

 

 

 

FLOW RATE ANALOG COMMON (GRAY)

 

10

 

 

 

I/O HARNESSES

RS485 INTEGRATION A (WHT/BLU)

1

TERMINAL

BLOCKS

RS485 INTEGRATION B (BLU/WHT)

2

 

RS485 INTEGRATION GROUND (SHIELD)

3

 

RS485 NETWORK A (WHT/ORG)

4

 

RS485 NETWORK B (ORG/WHT)

 

5

 

RS485 NETWORK GROUND (SHIELD)

6

 

CABLE

(50' STD.)/

(100' OPTION)

1MIX INPUT

2PURGE INPUT

3JOB COMPLETE INPUT

J2

4

EXTERNAL CLR CHG READY

 

5

RESET ALARM INPUT

6DIGITAL INPUT COMMON

1DIGITAL INPUT COMMON

2RECIPE BIT 0 INPUT

3RECIPE BIT 1 INPUT

J3

4

RECIPE BIT 2 INPUT

5

RECIPE BIT 3 INPUT

6RECIPE BIT 4 INPUT

7RECIPE BIT 5 INPUT

8RECIPE CHANGE INPUT

1DIGITAL OUTPUT COMMON/POWER

2PURGE/RECIPE CHG ACTIVE OUTPUT

3MIX ACTIVE OUTPUT

J4

4

MIX READY OUTPUT

5

FILL ACTIVE

6FLOW CAL. ACTIVE

7FLOW RATE ALARM OUTPUT

8DIGITAL OUTPUT COMMON/POWER

1DIGITAL OUTPUT COMMON/POWER

2SPECIAL OUTPUT #1

J5

3

SPECIAL OUTPUT #2

4

SPECIAL OUTPUT #3

5SPECIAL OUTPUT #4

6DIGITAL OUTPUT COMMON/POWER

(+24) YEL

(COM) GRAY BEACON ORG

BRN

RED

CABLE

J7

FO IN (BLK)

J8

FO OUT (BLU)

RJ45 RJ45 3'

P1

RJ45

BULKHEAD

3'

(25'-200' OPTIONS)

RJ45

RJ45

WEB SERVER

MODULE

312785C

39

Page 39
Image 39
Gateway 312785C important safety instructions System Electrical Schematic, Non-Hazardous Area