DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 21

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

-02

Forward directional switch is closed on

This status code will be displayed when P4 is greater

initial power up.

than 60% of battery voltage at initial key switch on.

MEMORY RECALL

CORRECTIVE ACTIONS

NO

 

 

SYMPTOM

Circuits valid

Control will not operate because of Static Return

to Off (SRO) lock out.

for

POSSIBLE CAUSE

Traction

Forward directional switch is closed on initial

Controller

start up (i.e. closure of battery, key switch or

 

seat switch).

 

Return directional switch lever to neutral and

 

then return lever to forward position.

Forward directional switch is welded closed or mis-adjusted to be held closed.

Replace or adjust directional switch to insure that it opens when the directional switch is returned to neutral.

Short circuit between P3 and P4.

Disconnect the wire from P4 and check for a short circuit between P3 and the wire that was connected to P4.

Defective control.

Replace the controller unit.

TROUBLE-SHOOTING DIAGRAM

KEY

SWITCH

 

 

L

SWITCHSEAT

STARTSW.

FORWARDSW.

REVERSESW.

 

 

 

 

 

 

P1

P17

P2

P6

P3

P4

P5

TRACTION

DESCRIPTION OF STATUS

STATUS CODE

 

-03

Reverse directional switch is closed on

initial power up.

MEMORY RECALL

CORRECTIVE ACTIONS

NO

 

 

SYMPTOM

Circuits valid

Control will not operate because of Static Return

to Off (SRO) lock out.

for

POSSIBLE CAUSE

Traction

Reverse directional switch is closed on initial

Controller

start up (i.e. closure of battery, key switch or

 

seat/deadman switch).

 

Return directional switch lever to neutral and

 

then return lever to reverse position.

Reverse directional switch is welded closed or mis-adjusted to be held closed.

Replace or adjust directional switch to insure that it opens when the directional switch is returned to neutral.

Short circuit between P3 and P5.

Disconnect the wire from P5 and check for a short circuit between P3 and the wire that was connected to P5.

Defective control. Replace the controller unit.

CAUSE OF STATUS INDICATION

This status code will be displayed when P5 is greater than 60% of battery voltage at initial key switch on.

TROUBLE-SHOOTING DIAGRAM

KEY

SWITCH

 

 

L

SWITCHSEAT

STARTSW.

FORWARDSW.

REVERSESW.

 

 

 

 

 

 

P1

P17

P2

P6

P3

P4

P5

January 2000

Page 21
Image 21
GE IC3645SR4U404N2 Description of Status Cause of Status Indication, Reverse directional switch is closed on