![](/images/new-backgrounds/1229371/22937141x1.webp)
DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROLPage 21
TRACTION | DESCRIPTION OF STATUS | CAUSE OF STATUS INDICATION |
STATUS CODE |
|
|
|
|
|
Forward directional switch is closed on | This status code will be displayed when P4 is greater | |
initial power up. | than 60% of battery voltage at initial key switch on. |
MEMORY RECALL | CORRECTIVE ACTIONS | |
NO | ||
| ||
| SYMPTOM | |
Circuits valid | Control will not operate because of Static Return | |
to Off (SRO) lock out. | ||
for | POSSIBLE CAUSE | |
Traction | ||
Forward directional switch is closed on initial | ||
Controller | start up (i.e. closure of battery, key switch or | |
| seat switch). | |
| • Return directional switch lever to neutral and | |
| then return lever to forward position. |
Forward directional switch is welded closed or
•Replace or adjust directional switch to insure that it opens when the directional switch is returned to neutral.
Short circuit between P3 and P4.
•Disconnect the wire from P4 and check for a short circuit between P3 and the wire that was connected to P4.
Defective control.
•Replace the controller unit.
KEY
SWITCH
|
| L | SWITCHSEAT | STARTSW. | FORWARDSW. | REVERSESW. |
|
|
|
|
|
| |
P1 | P17 | P2 | P6 | P3 | P4 | P5 |
TRACTION | DESCRIPTION OF STATUS | |
STATUS CODE |
| |
Reverse directional switch is closed on | ||
initial power up. | ||
MEMORY RECALL | CORRECTIVE ACTIONS | |
NO | ||
| ||
| SYMPTOM | |
Circuits valid | Control will not operate because of Static Return | |
to Off (SRO) lock out. | ||
for | POSSIBLE CAUSE | |
Traction | ||
Reverse directional switch is closed on initial | ||
Controller | start up (i.e. closure of battery, key switch or | |
| seat/deadman switch). | |
| • Return directional switch lever to neutral and | |
| then return lever to reverse position. |
Reverse directional switch is welded closed or
•Replace or adjust directional switch to insure that it opens when the directional switch is returned to neutral.
Short circuit between P3 and P5.
•Disconnect the wire from P5 and check for a short circuit between P3 and the wire that was connected to P5.
Defective control. Replace the controller unit.
CAUSE OF STATUS INDICATION
This status code will be displayed when P5 is greater than 60% of battery voltage at initial key switch on.
KEY
SWITCH
|
| L | SWITCHSEAT | STARTSW. | FORWARDSW. | REVERSESW. |
|
|
|
|
|
| |
P1 | P17 | P2 | P6 | P3 | P4 | P5 |
January 2000