DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 41

Section 4.6 TMM Status Codes

 

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-90

Traction motor temperature has

This status code will be displayed when the voltage at

exceeded maximum temperature limit.

the respective terminal of the TMM or Pump Logic

 

 

Card is at zero volts.

 

 

 

MEMORY RECALL

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Traction

User defined status code is displayed by switch

 

 

 

 

 

 

closure to battery negative.

 

 

 

 

 

 

Motor

Plug P16 (pump) is shorted to battery negative.

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

Defective input switch (shorted).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective TMM card.

 

P16

WHEN SR Series PUMP

 

 

 

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

Defective pump card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEG

 

 

 

 

 

 

 

 

 

 

 

 

SC90

 

 

 

 

 

 

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

-91

Pump motor temperature has

This status code will be displayed when the voltage at

exceeded maximum temperature limit.

the respective terminal of the TMM or Pump Logic

 

 

Card is at zero volts.

 

 

 

MEMORY RECALL

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Traction

User defined status code is displayed by switch

 

 

 

 

 

 

closure to battery negative.

 

 

 

 

 

 

Motor

Plug P11 (pump) is shorted to battery negative.

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

Defective input switch (shorted).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective TMM card.

 

P11

WHEN SR Series PUMP

 

 

 

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

Defective pump card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEG

 

 

 

 

 

 

 

 

 

 

 

 

SC91

 

 

 

 

 

 

 

 

January 2000

Page 41
Image 41
GE IC3645SR4U404N2, IC3645SP4U400N3 operation manual Temperature, TMM Status Codes