DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 43

TRACTION

DESCRIPTION OF STATUS

 

 

 

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-94

Traction motor brush wear indicator

This status code will be displayed when the voltage at

has detected worn brush.

the respective terminal of the TMM or Pump Logic

 

 

Card is at battery volts.

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

 

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Traction

User defined status code is displayed by motor

 

 

 

 

 

 

brush sensor closure to battery positive.

 

 

 

 

 

 

Motor

Plug P5 (pump) is shorted to positive.

 

 

 

 

 

 

Brush Wear

 

 

 

 

 

 

 

 

P5

WHEN SR Series PUMP

 

Indicator

Defective input switch (shorted).

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

Defective TMM card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective pump card.

 

 

 

 

 

 

 

 

 

 

 

USER SW

 

 

 

 

 

 

POS

 

 

 

 

 

 

 

 

 

 

 

 

 

SC94

 

 

 

 

 

 

 

 

 

 

 

 

TRACTION

DESCRIPTION OF STATUS

 

 

 

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

-94

Traction motor brush wear indicator

This status code will be displayed when the voltage at

had detected worn brush.

the respective terminal of the TMM or Pump Logic

 

 

Card is at zero volts.

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

 

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Traction

User defined status code is displayed by motor

 

 

 

 

 

 

brush sensor closure to battery positive.

 

 

 

 

 

 

Motor

.

 

 

 

 

 

 

Brush Wear

Plug P6 (pump) is shorted to positive.

 

 

 

 

 

 

Defective input switch (shorted).

 

P6

WHEN SR Series PUMP

 

 

 

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

 

 

 

 

 

 

 

Defective TMM card.

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective pump card.

USER SW

POS

SC94A

January 2000

Page 43
Image 43
GE IC3645SR4U404N2, IC3645SP4U400N3 operation manual Plug P5 pump is shorted to positive