DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 44

TRACTION

DESCRIPTION OF STATUS

 

 

 

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-95

Pump motor brush wear indicator has

This status code will be displayed when the voltage at

detected worn brush.

the respective terminal of the TMM or Pump Logic

 

 

Card is at battery volts.

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

 

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Pump

User defined status code is displayed by motor

 

 

 

 

 

 

brush sensor closure to battery positive.

 

 

 

 

 

 

Motor

Plug P8 (pump) is shorted to positive.

 

 

 

 

 

 

Brush Wear

 

 

 

 

 

 

 

 

P8

WHEN SR Series PUMP

 

Indicator

Defective input switch (shorted).

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

Defective TMM card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective pump card.

 

 

 

 

 

 

 

 

 

 

 

USER SW

 

 

 

 

 

 

POS

 

 

 

 

 

 

 

 

 

 

 

 

 

SC95

 

 

 

 

 

 

 

 

 

 

 

 

TRACTION

DESCRIPTION OF STATUS

 

 

 

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

-95

Pump motor brush wear indicator has

This status code will be displayed when the voltage at

detected worn brush.

the respective terminal of the TMM or Pump Logic

 

 

Card is at battery volts.

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

 

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

Circuits valid

Status code flashes “on and off”.

 

 

 

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

Pump

User defined status code is displayed by motor

 

 

 

 

 

 

brush sensor closure to battery positive.

 

 

 

 

 

 

Motor

Plug P9 (pump) is shorted to positive.

 

 

 

 

 

 

Brush Wear

 

 

 

 

 

 

 

 

P9

WHEN SR Series PUMP

 

Indicator

Defective input switch (shorted).

 

 

 

 

 

 

 

 

CONTROL IS USED

 

 

Defective TMM card.

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective pump card.

USER SW

POS

SC95A

January 2000

Page 44
Image 44
GE IC3645SP4U400N3, IC3645SR4U404N2 operation manual Plug P8 pump is shorted to positive