ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Section 6.5 Summary of Current Limit Adjustments

Page 63

MAXIMUM

FIELD CURRENT

ZERO

The " maximum fieldcurrent" setting

Maximum field

current is fixed at

is adjusted by Function 8. This

37.5 amps

function, along with the"armature

 

current limit", Function 4, sets the

 

maximum torque of the motor.

 

The " ratio" setting is adjusted by Function 26. This function sets the ratio between armature and field current when operating, I is

MOTOR

above FWS and less than 300 amps. Setting is the value of field current changed for each 100 amps of armature current changed.

The " error compensation" setting is adjusted by Function 23. This function is used to reduce the ripple in field current due to the interaction between motor field design and the digital field current regulation circuit. The value for this function will be defined by the GE application engineer.

The " minimum field current" setting is adjusted by Function 7. The function sets the top speed of the motor. If used.

The " field weakening start" setting is adjusted by Function 24. This function sets the armature current at which minimum field current will be achieved .

ARMATURE CURRENT

ZERO

The "full load transition point"

 

 

is calculated by the controlThis.

 

function sets the maximum field

 

current transition point at

 

approximately 300A armature

 

current.

MAXIMUM

The " ratio-2 " setting is adjusted by Function 6. This function sets the ratio between armature and field current when operating, I is

MOTOR

below FWS. Setting is the value of field current changed for each 100 amps of armature current changed.

The "armature current limit" setting is adjusted by Function 4. The function along with the

"maximum field current", Function 8, sets the maximum torque of the motor.