DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 36

TRACTION

DESCRIPTION OF

STATUS CODE

STATUS

-65

The line coil current is too high

during the run mode

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

 

SYMPTOM

Circuits valid

Control will not operate.

 

for

POSSIBLE CAUSE

Traction

- Shorted line contactor coil

Controller

- Short between wires connected to

 

line coil (wires #10 and 24)

 

If line coil resistance is correct:

 

Defective control.

 

Replace controller unit.

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the current limit in the line coil is exceeded during the run mode. The line contactor will drop out and the key switch will have to be recycled to reset the control.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

TRACTION

 

DESCRIPTION OF

STATUS CODE

 

STATUS

-66

The field current exceeds the

current limit of the field transistor.

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

 

 

SYMPTOM

Circuits valid

Control will not operate

Line contactor opens

for

POSSIBLE CAUSE

Traction

Shorted field F1 to F2

F1 or F2 terminals shorted to battery

Controller

 

positive (B+)

 

F1 or F2 terminals shorted to battery

 

 

negative (B-)

 

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the field transistor exceeds its specific current limit. The line contactor will drop out and the key switch will have to be recycled to restart the control.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

January 2000

Page 36
Image 36