DIAGNOSTIC STATUS CODES

TRANSISTOR PUMP CONTROL

Page 52

PUMP

DESCRIPTION OF STATUS

 

 

STATUS CODE

 

 

 

-180

Voltage at capacitor (1C) is less than

 

 

14 volts.

 

 

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

NO

 

 

 

SYMPTOM

 

 

Circuits valid

Pump control will not operate.

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

Pump

(Line contactor controlled by traction

 

 

control).

 

 

Controller

Line Contactor opened up during run.

 

 

 

Check connection from P17 to Line

 

 

 

coil (-) for loose connection.

 

 

 

Check connection from battery (+) to

LINE

 

Line coil (+) for loose connection.

 

 

 

 

 

Check power connection from battery

(+) to contactor L.

Check for blown fuse at pump control.

Check for dirty contactor tips.

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the voltage at P1 is less than 14 volts. This occurs typically in the run mode of operation.

TROUBLE-SHOOTING DIAGRAM

FU3

KEY SWITCH

TO TRACTION

 

 

 

FU6

 

 

 

 

 

 

P10 - BDI

 

 

 

 

 

 

 

 

 

PY7

 

P1

P2

P3

 

 

PY12

 

 

 

 

P21 P19 P12 PY10

 

 

 

 

 

 

PY11

FU1

 

 

 

LIMIT 3

LIMIT 2

LIMIT 1

 

 

 

SPEED

SPEED

SPEED

 

 

 

 

POS

POWER

 

FIELD

 

 

 

A1

 

ARMATURE

 

 

 

CONNECTIONS

 

TO

 

 

NEG

A2

 

 

TRACTION

 

 

 

 

CARD

 

 

 

 

 

 

 

 

PUMP

DESCRIPTION OF

STATUS CODE

STATUS

-181

Battery voltage is less than 14

volts.

MEMORY RECALL

CORRECTIVE ACTIONS

NO

 

SYMPTOM

Circuits valid

Pump control will not operate.

 

for

POSSIBLE CAUSE

 

Defective control fuse.

CAUSE OF STATUS INDICATION

This status code will be displayed when the battery voltage measured at P1 is less than 14 volts.

TROUBLE-SHOOTING DIAGRAM

FU3

KEY SWITCH

TO TRACTION

FU6

 

 

P10 - BDI

PY7

Pump

Check control fuse for open circuit,

Controller

replace fuse, if necessary.

 

Check connection from control fuse to

 

pump P1 for loose connections.

LINE FU1

+

-

P1 P2 P3

POS

A1

FIELD

 

 

POWER

ARMATURE

CONNECTIONS

NEG

A2

 

PY12

P21 P19 P12 PY10

PY11

SPEED LIMIT 3

SPEED LIMIT 2

SPEED LIMIT 1

TO

TRACTION

CARD

January 2000

Page 52
Image 52
GE IC3645SP4U400N3, IC3645SR4U404N2 Voltage at capacitor 1C is less than Volts, Battery voltage is less than