ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS | Page 62 |
FUNCTION 52 MODE 2 ARMATURE CONTROLLED
ACCELERATION
( Push CONT 5)
Same as Function 48.
This C/A takes effect when the Mode 2 settings are called for by the interactive Dash Display.
FUNCTION 53 MODE 2 FIELD WEAKENING START ( Push CONT 6)
Same as Function 49.
This FIELD WEAKENING START takes effect when the Mode 2 settings are called for by the interactive Dash Display.
FUNCTION 54 MODE 1 FW RATIO ( Push CONT 7 )
Same as Function 50.
This FW RATIO takes effect when the Mode 2 settings are called for by the interactive Dash Display.
FUNCTION 55 MODE 2 MAX ARMATURE % ON
( Push CONT 8 )
Same as Function 51.
This MAX ARMATURE % ON takes effect when the Mode 2 settings are called for by the interactive Dash Display.
FUNCTION 56 MODE 3 ARMATURE CONTROLLED ACCELERATION ( Push CONT 9)
Same as Function 48.
This C/A takes effect when the Mode 3 settings are called for by the interactive Dash Display.
FUNCTION 57 MODE 3 FIELD WEAKENING START
( Push CONT 10)
Same as Function 49.
This FIELD WEAKENING START takes effect when the Mode 3 settings are called for by the interactive Dash Display.
FUNCTION 58 MODE 3 FW RATIO ( Push CONT 11 )
Same as Function 50.
This F/W RATIO takes effect when the Mode 3 settings are called for by the interactive Dash Display.
FUNCTION 59 MODE 3 MAX ARMATURE % ON
( Push CONT 12 )
Same as Function 51.
This MAX ARMATURE % ON takes effect when the Mode 3 settings are called for by the interactive Dash Display.
FUNCTION 60 MODE 4 ARMATURE CONTROLLED ACCELERATION ( Push CONT 13)
Same as Function 48.
This C/A takes effect when the Mode 4 settings are called for by the interactive Dash Display.
FUNCTION 61 MODE 4 FIELD WEAKENING START
( Push CONT 14)
Same as Function 49.
This FIELD WEAKENING START takes effect when the Mode 4 settings are called for by the interactive Dash Display.
FUNCTION 62 MODE 4 FW RATIO ( Push CONT 15 )
Same as Function 50.
This F/W RATIO takes effect when the Mode 4 settings are called for by the interactive Dash Display.
FUNCTION 63 MODE 4 MAX ARMATURE % ON ( Push CONT ESC )
Same as Function 51.
This MAX ARMATURE % ON takes effect when the Mode 4 settings are called for by the interactive Dash Display.
January 2000