ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page 62

FUNCTION 52 MODE 2 ARMATURE CONTROLLED

ACCELERATION

( Push CONT 5)

Same as Function 48.

This C/A takes effect when the Mode 2 settings are called for by the interactive Dash Display.

FUNCTION 53 MODE 2 FIELD WEAKENING START ( Push CONT 6)

Same as Function 49.

This FIELD WEAKENING START takes effect when the Mode 2 settings are called for by the interactive Dash Display.

FUNCTION 54 MODE 1 FW RATIO ( Push CONT 7 )

Same as Function 50.

This FW RATIO takes effect when the Mode 2 settings are called for by the interactive Dash Display.

FUNCTION 55 MODE 2 MAX ARMATURE % ON

( Push CONT 8 )

Same as Function 51.

This MAX ARMATURE % ON takes effect when the Mode 2 settings are called for by the interactive Dash Display.

FUNCTION 56 MODE 3 ARMATURE CONTROLLED ACCELERATION ( Push CONT 9)

Same as Function 48.

This C/A takes effect when the Mode 3 settings are called for by the interactive Dash Display.

FUNCTION 57 MODE 3 FIELD WEAKENING START

( Push CONT 10)

Same as Function 49.

This FIELD WEAKENING START takes effect when the Mode 3 settings are called for by the interactive Dash Display.

FUNCTION 58 MODE 3 FW RATIO ( Push CONT 11 )

Same as Function 50.

This F/W RATIO takes effect when the Mode 3 settings are called for by the interactive Dash Display.

FUNCTION 59 MODE 3 MAX ARMATURE % ON

( Push CONT 12 )

Same as Function 51.

This MAX ARMATURE % ON takes effect when the Mode 3 settings are called for by the interactive Dash Display.

FUNCTION 60 MODE 4 ARMATURE CONTROLLED ACCELERATION ( Push CONT 13)

Same as Function 48.

This C/A takes effect when the Mode 4 settings are called for by the interactive Dash Display.

FUNCTION 61 MODE 4 FIELD WEAKENING START

( Push CONT 14)

Same as Function 49.

This FIELD WEAKENING START takes effect when the Mode 4 settings are called for by the interactive Dash Display.

FUNCTION 62 MODE 4 FW RATIO ( Push CONT 15 )

Same as Function 50.

This F/W RATIO takes effect when the Mode 4 settings are called for by the interactive Dash Display.

FUNCTION 63 MODE 4 MAX ARMATURE % ON ( Push CONT ESC )

Same as Function 51.

This MAX ARMATURE % ON takes effect when the Mode 4 settings are called for by the interactive Dash Display.

January 2000

Page 62
Image 62
GE IC3645SP4U400N3 Function 52 Mode 2 Armature Controlled Acceleration, Function 55 Mode 2 MAX Armature % on