ADJUSTABLE FEATURES

 

TRANSISTOR PUMP CONTROLS

Page 65

of 0.375 volts each whereas, a setting of 4 will be added in 15 steps of 0.375 volts each.

SPEED / TORQUE

COMPENSATION TABLE

 

VOLTAGE

 

 

VOLTAGE

SETTING

DROP

 

SETTING

DROP

2

11.44

 

17

1.34

3

7.60

 

18

1.27

4

5.72

 

19

1.20

5

4.57

 

20

1.14

6

3.81

 

21

1.09

7

3.27

 

22

1.04

8

2.86

 

23

0.99

9

2.54

 

24

0.95

10

2.28

 

25

0.91

11

2.08

 

26

0.88

12

1.90

 

27

0.85

13

1.76

 

28

0.82

14

1.63

 

29

0.79

15

1.52

 

30

0.76

16

1.43

 

31

0.74

FUNCTION 17:

CARD TYPE SELECTION

 

 

(Push CONT 2)

 

 

This function should be set in accordance with the control type in use in the vehicle:

 

Without Pump

Function

Ctr/PMT

High C/L

 

BDI Lockout

63 to 71

BDI Lockout means that the BDI signal from the traction control must be present in order for the pump control to operate. This control will stop operation when the battery state of charge reaches 10%.

Settings for these functions should be made in between the values shown.

Warning: These setting must be changed by authorized personnel only, following instructions supplied by the manufacturer. Card type selection must be made within the capabilities of the TRANSISTOR control panel used and the supporting electro-mechanical devices. Failure to comply with proper application standards could result in mis-operation or damage to the control and/or motors.

FUNCTION 28: FAULT COUNT POINTER (Push CONT 13)

This register contains the location of the last stored status code recorded of the 16 stored status codes. These stored

status codes have caused a PMT controller shutdown and/or disruption of normal vehicle operation.

To determine which stored status code was the last one recorded, read the number stored in Function 28. Using the Memory Map (See Section 8.1) for your logic card, match the “stored status code pointer number” (the number shown in (bold italics) in the HS (Handset) number column) on the memory map, with the number obtained from Function 28. This will be the last stored status code recorded.

Note: When scrolling the stored status code register, the register always starts at status code 1 and scrolls to status code 16. Instructions for scrolling the register are in Section 6.3.2 of this instruction booklet.

Note: The following functions have function numbers larger than the numbers on the Handset keyboard. To access these functions, push the CONT key and the number shown in the following instructions at the same time. THE KEY SWITCH MUST BE CLOSED.

FUNCTION 48: MODE 1 - CONTROLLED ACCELERATION (Push CONT 1)

This function allows for the adjustment of the rate of time it takes for the control to accelerate to 96% applied battery voltage to the motor on hard acceleration.

Range

0.1 to 22.0 seconds

Setting

0 to 255

Resolution

0.084 seconds per set unit

Example: Setting of 20 = 1.8 seconds C/A

FUNCTION 49: MODE 1 - SPEED LIMIT 2 (SL2) (Push CONT 2)

This function allows for the adjustment of the speed limit (maximum battery volts to the motor) when the SL2 limit switch input signal is received by the control card. SL2 limit switch is a normally open switch connected to battery negative, the switch closing enables speed limit.

Range

0% to 100% battery volts

Setting

0 to 255

Resolution

0.375 volts per set unit

Example: Setting of 50=18.75 volts

FUNCTION 50: MODE 1 - SPEED LIMIT 3 (SL3)

(Push CONT 3)

This function allows for the adjustment of the speed limit (maximum battery volts to the motor) when the SL3 limit