DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 38

January 2000

TRACTION

STATUS CODE DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION

-68 The PMT enable signal from the

auxiliary (slave) control to the master

control drops below 5V.

This status code will be displayed when the voltage at

the master PL21 drops below 5V.

MEMORY RECALL

YES CORRECTIVE ACTIONS

Circuits valid

for

Traction

Controller

SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Auxiliary control shut down.
=Check auxiliary control for stored faults.
Verify connection between the master control P21 and the
auxiliary/slave control P10.

TROUBLE-SHOOTING DIAGRAM

POWER CONNECTIONS
LEFT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
FU1
POWER CONNECTIONS
RIGHT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
FU5 KEY SWITCH
L
P7
P1
P17 P2 P6 P9
P3 P12 P8
P4 P5
SEAT SW.
START SW.
FORWARD SW.
REVERSE SW.
BRAKE SW.
P10 P21
ACC POT STEER ANGLE
POT BDI INTERRUPT
P18 P7 P12 P6P2P1 P3 P4 P5
P10 P13
LINE
P16 P15
PY7
PY12
PY10
PY11
P16
P15
AUTO REGENERATIVE
BRAKING ENABLE
PMT ENABLE OUTPUT
25
P18
STEER PUMP
CONTACTOR DRIVER
P11
REGEN OUTPUT
SIGNAL
29 50 30 66 65
PY7
PY12
PY10
PY11
PLUG PY
CONNECTIONS
PLUG PY
CONNECTIONS
8
6
15
710
12-1
10
SP
P1
P5
60 24
P4
12
P2
FU7
TO ACCESSORIES
FU6 P3 12-1
OSCILLATOR CARD
LEFT CONTROL
OSCILLATOR CARD
RIGHT CONTROL
3
A2
S1
TMM7 A2
A1
5
13A
A2
A1
+
-
SP
A1
A2
SP
FU4
89
88
TMM7
2
43
A1
S2
FU2
P
P