DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 23

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-07

Accelerator input voltage too high on

This status code will be displayed when the

power up after initial key switch

accelerator input voltage at P7 is higher than 4.2

 

closure.

volts, and a directional contactor is picked up.

MEMORY RECALL

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

NO

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

 

 

 

Circuits valid

Control will not operate when accelerator pedal

 

 

 

 

 

 

 

 

 

is depressed or status code -07 is displayed

 

 

 

 

 

 

 

 

 

for

then disappears when the vehicle starts to

 

 

 

 

 

 

 

 

 

Traction

accelerate.

 

 

 

P7

 

 

 

POSSIBLE CAUSE

 

 

 

 

 

 

Controller

Accelerator input mis-adjusted or defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input voltage at P7 should be less than 3.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

volts. Adjust or replace accelerator unit to

 

 

KEY

 

 

NEGATIVE

 

insure that the voltage at P7 will vary from 3.5

 

 

 

 

 

 

SWITCH

 

 

 

volts to less than .5 volts when the pedal is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

depressed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open circuit between battery negative and P7 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

accelerator input circuit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for broken wires or loose connections

 

 

ACC POT

 

 

 

 

or open potentiometer / voltage supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short circuit from battery positive to wiring in accelerator input circuit.

Disconnect wire from P7 and measure voltage at wire to negative. Should be zero volts for potentiometer type and less than 3.7 volts for solid state type accelerator input.

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-08

Accelerator input voltage too low on

This status code will be displayed when the

power up after initial key switch

accelerator input voltage at P7 is less than 3.0 volts,

 

closure.

and any of the following connections are opened and

 

 

closed: battery plug or key switch.

MEMORY RECALL

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

NO

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

 

 

 

Circuits valid

Control will not operate.

 

 

 

P7

 

 

 

 

 

 

 

 

 

 

for

POSSIBLE CAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Traction

Accelerator input mis-adjusted or defective.

 

 

 

 

 

 

 

 

 

Input voltage at P7 should be more than 3.0

 

 

KEY

 

 

 

 

 

Controller

volts. Adjust or replace accelerator unit to

 

 

 

 

NEGATIVE

 

SWITCH

 

 

 

insure that the voltage at P7 is more than 3.0

 

 

 

 

 

 

 

volts before depressing pedal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short circuit between battery negative and P7 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

accelerator input circuit.

 

 

 

 

 

 

 

 

 

 

Disconnect wire from P7. Check for short

 

 

ACC POT

 

 

 

 

circuit from wire to battery negative.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective Control

Disconnect wire from P7. Measure voltage from P7 to negative. Voltage should be greater than 4.5 volts, if not, replace control.

January 2000

Page 23
Image 23
GE IC3645SR4U404N2, IC3645SP4U400N3 operation manual KEY Negative