DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 28

TRACTION

DESCRIPTION OF STATUS

 

 

 

 

 

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-27

Control’s power supply is less than 10 This status code will be displayed when the control’s

Volts DC.

power supply is less than 10 volts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMORY RECALL

CORRECTIVE ACTIONS

 

 

 

 

 

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

 

 

 

 

KEY

Circuits valid

Line contactor opens and closes, then can only

 

 

 

 

 

FU3

 

 

be closed by opening and closing the key

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

for

switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Traction

POSSIBLE CAUSE

 

 

 

 

 

FU5

 

 

 

 

 

 

 

Controller

Discharged Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check battery to insure proper state of charge.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage may be dropping below 10 Volts DC

 

 

 

+

 

 

 

 

 

 

 

 

under load.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose connection at P1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insure that the wire connection at P1 is tight.

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1 P2

 

 

 

 

 

 

 

 

 

NEG

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective control.

Replace controller unit.

TRACTION

DESCRIPTION OF STATUS

STATUS CODE

 

-28

Motor field current is too high during

the run mode.

MEMORY RECALL

CORRECTIVE ACTIONS

YES

 

Circuits valid

SYMPTOM

for

Control will not operate.

 

Traction

POSSIBLE CAUSE

Controller

Continued operation of vehicle in high motor

current condition.

 

Operate vehicle at lower motor current

 

condition for 70 seconds.

 

Function 7 is mis-adjusted to allow higher than

 

normal motor field current.

 

Adjust function per OEM instructions.

 

 

CAUSE OF STATUS INDICATION

This status code will be displayed when the current draw in the motor field is sustained above a preset limit for longer than 70 seconds.

TROUBLE-SHOOTING DIAGRAM

 

 

 

 

BRAKE SW.

 

 

FU5

P2 KEY SWITCH P1

SEATSW.

STARTSW.

FOR.SW.

REV. SW.

FU7

 

 

SP

 

TO

P5

 

 

 

 

 

 

L

 

 

 

 

FU6

ACCESSORIES

P4

 

 

 

 

P3

 

 

 

 

 

PY7

 

 

 

 

P4

 

 

PY12 P18

P17 P1 P2

P6

P3

P5

 

PY10

 

OSCILLATOR CARD

P7

P10 P9 P12 P8

 

PY11

 

LEFT CONTROL

 

 

 

LINE FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

STEER

FU2

 

 

 

 

 

 

ANGLE

 

 

 

 

ACC POT

POT

 

 

 

 

 

 

+

FU4

 

 

 

 

 

 

 

BDI INTERRUPT

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

POS

A1

F1

FIELD

ARMATURE

NEG

A2

F2

FIELD

ARMATURE

-

 

 

POWER

 

 

 

 

 

 

POS

A1

F1

 

 

 

SP

CONNECTIONS

 

 

POWER

 

 

 

 

LEFT CONTROL

 

 

CONNECTIONS

 

 

 

 

NEG

A2

F2

 

 

RIGHT CONTROL

 

 

P

SP

 

 

 

 

 

 

 

 

 

 

January 2000

Page 28
Image 28
GE IC3645SP4U400N3 Volts DC Power supply is less than 10 volts, Motor field current is too high during, Run mode