DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROLPage 45

TRACTION

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

STATUS CODE

 

 

 

 

 

-99

Maintenance alert and speed limit.

This status code will be displayed when the “normal”

 

hour meter exceeds the “maintenance alert hours”

 

 

setting for the vehicle.

MEMORY RECALL

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

YES

 

 

 

SYMPTOM

 

Circuits valid

Status code is displayed for 4 seconds when the

 

key switch is first turned on, and/or the vehicle

 

for

may run at a reduced speed.

NO DIAGRAM

Traction

CUSTOMER SELECTED SETTING WITH THE

 

Controller

HANDSET:

 

 

User defined status code is displayed when the

 

 

normal hour meter reading exceeds the

USER SHOULD PERFORM THE DESIRED

 

programmed “maintenance alert hours” setting

 

selected by the user

 

MAINTENANCE FUNCTION

 

Maintenance Code Hour Meter, Functions 19

 

and 20, are programmed with the Handset and

 

 

command the display of status code -99.

 

 

If desired, Maintenance Code Speed Limit,

 

 

Function 13, can be programmed with the

 

 

Handset.

 

 

User should perform the desired maintenance

 

 

function. Re-set maintenance alert hour meter

 

 

after maintenance is performed.

 

 

 

 

January 2000

Page 45
Image 45
GE IC3645SR4U404N2, IC3645SP4U400N3 operation manual Corrective Actions TROUBLE-SHOOTING Diagram YES