DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROLPage 51
PUMP | DESCRIPTION OF STATUS | CAUSE OF STATUS INDICATION | |
STATUS CODE |
|
| |
|
|
| |
| Capacitor volts are low before the line | This status code will be displayed during “key on” when | |
contactor closes. (Internal card | the capacitor volts is less than 85% of battery volts at | ||
| function during precharge) | initial key switch on. | |
|
|
| |
MEMORY RECALL | CORRECTIVE ACTIONS | ||
NO | |||
|
|
Circuits valid
for
SYMPTOM
Pump control will not operate.
FU3 | KEY SWITCH | TO TRACTION |
FU6 |
| |
| P10 - BDI |
PY7
Pump
Controller
POSSIBLE CAUSE
Defective control fuse.
•Check control fuse for open circuit, replace fuse, if necessary.
Defective control.
•Replace controller unit.
Note: Repeated “charging/discharging” the capacitors during troubleshooting will cause status code 51. Also “do not” connect any loads to the load side of the line contactor.
LINE FU1
+
-
P1 P2 P3
POWER | A1 | FIELD | |
POS | ARMATURE | ||
CONNECTIONS | |||
| |||
NEG | A2 |
|
PY12
P21 P19 P12 PY10
PY11
SPEED LIMIT 3 | SPEED LIMIT 2 | SPEED LIMIT 1 |
TO
TRACTION
CARD
PUMP | DESCRIPTION OF | |
STATUS CODE | STATUS | |
| Controller “motor current | |
sensor” input voltage polarity | ||
MEMORY RECALL | check. | |
CORRECTIVE ACTIONS | ||
NO | ||
Circuits valid | SYMPTOM | |
Pump control will not operate. | ||
for | ||
|
CAUSE OF STATUS INDICATION
This status code will be displayed when the voltage input to motor current sensor is of the wrong polarity.
FU3 | KEY SWITCH | TO TRACTION |
FU6 |
| |
| P10 - BDI |
PY7
Pump | POSSIBLE CAUSE |
Controller | Control is defective. |
| • Replace controller unit. |
LINE FU1
+
-
P1 P2 P3
POS | A1 | FIELD | |
| |||
| POWER | ARMATURE | |
CONNECTIONS | |||
NEG | A2 | ||
|
PY12
P21 P19 P12 PY10
PY11
SPEED LIMIT 3 | SPEED LIMIT 2 | SPEED LIMIT 1 |
TO
TRACTION
CARD
January 2000