DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL Page 48
January 2000
PUMP
STATUS CODE DESCRIPTION OF
STATUS CAUSE OF STATUS INDICATION
-142 Pump Controller “motor current
sensor” input is missing. This status code is displayed when the voltage at the
current sensor is greater than 0.1 volts with no current
flowing in the motor circuit.
MEMORY RECALL
NO CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
No power to pump motor in
control range.
POSSIBLE CAUSE
Control is defective.
=Replace controller unit.
POWER
CONNECTIONS
POS A1
NEG A2
FIELD
ARMATURE
+
-
FU1
FU3 KEY SWITCH
P1 P2 P3 P12
LINE
FU6
P19P21
TO
TRACTION
CARD
SPEED LIMIT 1
SPEED LIMIT 2
SPEED LIMIT 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11
PUMP
STATUS CODE DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-143 Pump Controller “motor current
sensor” input is too low. This status code is displayed when the voltage at the
current sensor is greater than 0.1 volts with no current
flowing in the motor circuit.
MEMORY RECALL
NO CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Controller
SYMPTOM
No power to pump motor in
control range.
POSSIBLE CAUSE
Control is defective.
=Replace controller unit.
POWER
CONNECTIONS
POS A1
NEG A2
FIELD
ARMATURE
+
-
FU1
FU3 KEY SWITCH
P1 P2 P3 P12
LINE
FU6
P19P21
TO
TRACTION
CARD
SPEED LIMIT 1
SPEED LIMIT 2
SPEED LIMIT 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11