Installation Instructions

3CONNECT THE WATER LINE

Squeeze the ends of the hose clamp (3) from the kit with pliers and slide the clamp over the water tube inlet.

While still squeezing the clamp, insert the

plastic water line into the inlet as far as it will go (approximately 1[25 mm]).

Then slide the clamp downward to capture the plastic water line in place.

Make sure the fill tube is aimed down.

If the condenser mounting screw was removed, secure the condenser to the refrigerator by replacing the mounting clip and screw.

DO NOT OVER-TIGHTEN THE SCREW.

Water tube inlet

3

4ATTACH THE PLASTIC WATER LINE

Fasten the plastic water line to the back of the cabinet with adhesive-backed fasteners (5), spacing the fasteners as shown to take up the slack in the line. (It may be necessary to remove the screw from the top right condenser mounting clip for better access to the water tube inlet).

5

WATER VALVE INSTALLED

Refer to the Water Line Installation Instructions for connection to the home water supply. After water line installation is completed, set the icemaker power switch to ON.

The icemaking cycle will not begin until the icemaker and freezer compartment reach operating temperature, then icemaking will begin automatically.

Adhesive-backed fasteners for plastic water line

25

Page 26
Image 26
GE IM-6 installation instructions Do not OVER-TIGHTEN the Screw