USER FUNCTIONS

USER FUNCTIONS

Remote Phone Control Feature

The LYNX Touch Series is equipped with a remote interactive phone capability that permits access to the security system from any off-site touch-tone telephone using all user codes. The system will provide the appropriate voice messages and any system beeping sounds indicating the status of the security system over the phone line. Refer to Summary of Audible Notification section for further information.

The following functions can be performed from any remote touch-tone telephone:

Disarm the system.

Arm the system in STAY or AWAY mode.

Bypass zones.

Check system status.

The remote access session will be aborted if:

A report must be sent.

Any local or wireless key entry is made.

User Code is not entered within eight (8) seconds of call pickup (during the “system…..system announcement).

No keys are depressed for a period of 15 seconds and while no announcement has been made by the system. Any remote key entry will, however extend this timeout back to 15 seconds.

It will not be possible to begin a remote access session if:

A report must be sent

The system is in any Test mode.

Panel is in shutdown mode (programmed by your installer).

Using Remote Phone Control Feature

Dial the controls’s phone number. If no answering machine is present, the control will pick up between 1 and 14 rings, depending on the number programmed by your installer and will periodically announce “SYSTEM ENTER CODE”. If an answering machine is on the premises, you need to dial the premises and hang up on the first ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number again. The control will pick up and periodically announce “SYSTEM”.

Remote Phone Control Commands

Enter User Code (within eight seconds). Upon entering remote phone control mode the Lynx will announce “System, enter code”.

To remotely disarm system:

User Code + [1]

To remotely arm in AWAY mode:

User Code + [2]

To remotely arm in STAY mode:

User Code + [3]

To remotely arm in AWAY or STAY mode with no delay:

User Code + [2] or [3] + [0]

To remotely Bypass zones:

User Code + [6] + zone no.

To remotely activate Force Bypass:

User Code + [6] + [#]

To remotely check system status:

[]

To end remote phone session: Hang Up or

User Code + [9]

Notes: (1) Check with your installer to see if the Force Bypass mode has been enabled.

(2)When bypassing zones, make sure a confirmation beep sounds for each zone that has been bypassed.

– 67 –