Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Table of Device Addresses, Wire, Size

Models: VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA K5305-1V5

1 80
Download 80 pages 15.84 Kb
Page 11
Image 11
Keypad Notes

Mounting and Wiring the Control

Keypad Notes

ARMED

READY

1

OFF

 

 

 

 

4

 

 

2

AWAY

 

 

MAX

 

3

 

 

5

 

STAY

7INST

 

TEST

 

ANT

8

6

 

 

 

 

CODE

 

BYPASS

 

READY

0

 

9

CHIME

 

 

 

 

 

 

 

 

 

 

#

 

Long Range Radio Connections

Set device addresses. Refer to the instructions included with the devices and set each address according to the Table of Devices Addresses.

See Keypad Programming Fields (fields *190-*196) in Section 4. Data Field Programming for details on enabling keypad addresses, assigning keypad partitions and selecting keypad sounding options.

IMPORTANT: Each keypad must be assigned a unique, predefined address, from 16 to

23.The first keypad is address 16 (default = partition 1, all sounds enabled).

TOUCH SCREEN KEYPAD (AUI) NOTES:

Use of up to 2 AUI devices (e.g., 6270, Symphony) is independent from standard keypads and does not affect the number of standard keypads the system can support.

AUI devices must be set for either address 1 or address 2, depending on which unit is enabled in field *189.

To ensure proper AUI device operation, connect only to controls having microprocessor version 3.0 or higher, and use AUI devices with the following rev levels: 6270 series use version 1.0.9 or higher; 8132/8142 (Symphony) series use version 1.1.175 or higher.

Connect the data in/data out terminals and voltage input terminals of the Long Range Radio to the control's keypad connection points.

Set the radio’s address to “03” following the instructions provided with the radio.

Use compatible Long Range Radios (e.g., 7720PLUS, 7820, 7835C, or 7845C).

Wire Run Chart For Devices* Drawing Aux Power From The Control (12V+ & 12V–)

Wire

TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUN

Size

50 mA or less

100 mA

300 mA

500 mA

600 mA

#22

900 ft (274m)

450 ft (137m)

150 ft (46m)

90 ft (27m)

75 ft (23m)

#20

1400 ft (427m)

700 ft (213m)

240 ft (73m)

140 ft (43m)

120 ft (37m)

#18

1500 ft (457m)

1100 ft (335m)

350 ft (107m)

220 ft (67m)

170 ft (52m)

#16

1500 ft (457m)

1500 ft (457m)

550 ft (168m)

350 ft (107m)

270 ft (82m)

*Includes Keypads, RF Receivers, Zone Expander/Relay Units, 4285/4286 Phone Module, and Long Range Radio.

Maximum wire lengths for any device that is homerun to the control can also be determined from the Wiring Run Chart, based on the current draw of that device alone.

The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad conductor cable is used (750 feet if shielded cable is used). This restriction is due to the capacitive effect on the data lines when quad cable is used.

Table of Device Addresses

This Device

Uses Address

Reports as††

Enabled By…

RF Receiver

00

100

*56 zone programming: input device type entry

AUI 1

01

101

automatic if AUI enable field *189 enabled for AUI 1

AUI 2

02

102

automatic if AUI enable field *189 enabled for AUI 2

Long Range Radio

03

103

automatic if output to long range radio field *29 enabled

4286 Voice Module

04

104

automatic if phone module access code field *28 enabled

Zone Expanders (4219/4229):

 

 

*56 zone programming: input device type, entry 2, then:

module 1 (for zones 09 - 16)

07**

107

automatic if zone no. 9-16 set as AW type or relay assigned

module 2 (for zones 17 - 24)

08

108

automatic if zone no. 17-24 set as AW type or relay assigned

module 3 (for zones 25 - 32)

09

109

automatic if zone no. 25-32 set as AW type or relay assigned

module 4 zones 33 - 40

10

110

automatic if zone no. 33-40 set as AW type or relay assigned

module 5 zones 41 - 48

11

111

automatic if zone no. 41-48 set as AW type or relay assigned

Relay Modules (4204):

 

 

*79 output device programming: device address prompt:

module 1

12

112

entered at device address prompt

module 2

13

113

entered at device address prompt

module 3

14

114

entered at device address prompt

module 4

115

entered at device address prompt

 

15

 

 

Keypads:

 

 

data field programming as listed below:

keypad 1

16

n/a

always enabled for partition 1, all sounds enabled.

keypad 2

17

n/a

data field *190

keypad 3

18

n/a

data field *191

keypad 4

19

n/a

data field *192

keypad 5

20

n/a

data field *193

keypad 6

21

n/a

data field *194

keypad 7

22

n/a

data field *195

keypad 8

23

n/a

data field *196

5800TM Module

28

n/a

automatic

** address 07 not available if zone-doubling enabled

† 4219/4229 addresses 9-11 and 4204 addresses 14-15 apply to the VISTA-20P.

††Addressable devices are identified by “1” plus the device address when reporting. Enter a report code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.

2-5

Page 11
Image 11
Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Table of Device Addresses, Mounting and Wiring the Control