Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Menu Mode Programming, Confirm

Models: VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA K5305-1V5

1 80
Download 80 pages 15.84 Kb
Page 43
Image 43
Not Confirmed

Menu Mode Programming

 

 

Confirm

 

XMIT TO CONFIRM

 

[] to continue

 

PRESS TO SKIP

 

• If “Yes” was entered at the SET TO CONFIRM? prompt previously (see first prompt

 

 

 

 

following entry into the ∗58 Expert Programming Mode), the display on the left will

 

 

appear. Confirm serial and loop numbers by activating the wireless key.

 

 

IMPORTANT:

 

 

When confirmed, the key is not active for arming/disarming until it is assigned to a user

 

 

number (using the assigning attributes command, attribute “4”). See System Operation

 

 

section for procedure.

 

 

Not Confirmed

 

Entd A022-4063

 

[] to continue

 

Rcvd A022-4064

 

If the serial number transmitted does not match the serial number entered, a display

 

 

 

 

similar to the one shown will appear. If the loop number does not match, it will also be

 

 

displayed.

 

 

If so, activate the button on the wireless key once again. If a match is not obtained (i.e.,

 

 

summary display does not appear), press the [#] key and then enter the correct serial

 

 

number.

 

 

If the serial number transmitted matches the serial number entered, the keypad will beep

 

 

3 times and will return you to the Zone Number prompt to enter the starting zone for the

 

 

next wireless key.

 

 

Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt.

 

 

NOTE: Following the successful enrollment of each wireless device, remove ONE of the

 

 

serial number labels from the device and affix it in the appropriate column on the ZONE

 

 

PROGRAMMING worksheet of the Programming Form; then enter the other information

 

 

(zone number, zone type, loop number, etc.) relevant to that device.

 

 

Wireless Key Predefined Default Templates

 

 

LOOP 3

YOU MUST

OFF

LOOP 2

PROGRAM

ON

 

THIS BUTTON

 

LOOP 1

LOOP 4

 

ENROLL AS "BR"

5 8 0 4 - 0 0 1 - V 1

5804 Wireless Key Transmitter

Note:

These transmitters are not intended for use in UL installations.

GREEN/YELLOW

 

 

 

LED

 

 

LOOP 2

RED/YELLOW

 

 

LOOP 4

LED

 

 

 

 

(YOU MUST

 

 

 

 

 

 

PROGRAM

 

 

 

THIS BUTTON)

LOOP 3

 

 

 

 

 

 

LOOP 1

• •

•••

••

ENROLL AS "BR"

••

 

 

 

5 8 0 4 B D - 0 0 7 - V 0

5804BD 2-Way Wireless Key

Transmitter

 

For 5804

 

 

 

For 5804BD

 

TEMPLATE 1

Loop

Function

Zone Type

 

TEMPLATE 4

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

No Response

23

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

No Response

23

 

 

4

Disarm

22

TEMPLATE 2

Loop

Function

Zone Type

 

TEMPLATE 5

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

TEMPLATE 3

Loop

Function

Zone Type

 

TEMPLATE 6

Loop

Function

Zone Type

 

1

24-hour audible

7

 

 

1

24-hour audible

7

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

5-7

Page 43
Image 43
Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA, K5305-1V5 Wireless Key Predefined Default Templates, Confirm