Installing a Keyswitch

Installation and Setup Guide

Installing a Keyswitch

Keyswitch Connections

GREEN

RED

1.Connect the 4146 keyswitch's normally open momentary switch to a zone’s (2-8) terminals. Remove the 2000 ohm EOL resistor if connected across the selected zone.

2.Using a standard keypad cable as shown:

Connect the yellow and white keyswitch wires to trigger connector pin 3 (+12V). Connect the Red and Green LED wires to the appropriate output 17/output 18 trigger connector pins.

3.Connect a 2000 ohm EOL resistor across the momentary switch.

4.You can wire an optional closed-circuit tamper switch (model 112) in series with the zone. If the switchplate is then removed from the wall, the tamper will open, disabling keyswitch operation until the system is next disarmed from the keypad.

If the tamper is opened when the system is armed, an alarm will occur.

8-PIN TRIGGER CONNECTOR

1

KEY

3

4

5

6

7

8

 

 

 

 

 

 

 

(YELLOW)

(RED)

(GREEN)

OUTPUT 17

+12 AUX.

OUTPUT 18

STANDARD

KEYPAD

4146 KEYSWITCH

11

TYPICAL ZONE ON CONTROL BOARD

10

CABLE(ARMED)

RED

YELLOW

(READY)

GREEN

WHITE

 

820

820

ohms

ohms

BLACK

 

RED

 

TAMPER

 

SWITCH (N. C.)

BROWN

BROWN

LOCK

 

SWITCH (N. O.)

BLUE

BLUE

EOLR

(use appropriate value)

00-trigcon-004-V1

Figure 12. Keyswitch Wiring Connections

Keyswitch Notes

UL A UL Listed keyswitch is required for fire installations and UL commercial and residential burglar alarm installations. The Ademco 4146 keyswitch is UL Listed.

If a keyswitch is used on:

an installation that transmits opening and closing signals, the keyswitch zone must be programmed to send opening and closing signals.

a UL commercial burglar alarm installation, the keyswitch’s tamper switch must be connected in to the alarm system. This tamper switch zone must also be programmed for Zone Type 05 – Trouble by Day / Alarm by Night.

a fire alarm installation, the keyswitch must be located next to an alphanumeric display keypad.

Use 4146 keyswitch or any N.O. keyswitch.

Use only one keyswitch per partition.

When using a keyswitch, the zone it is connected to is no longer available for use as a protective zone.

Use *56 Menu mode to program the keyswitch zone and assign it zone type 77.

Use *80 Menu mode to program the LED functions: program outputs 17 and 18 for system operation zone type 78 (red LED) and 79 (green LED) as appropriate (see Output Device Programming section).