Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA, K5305-1V5 Pager Programming Fields

Models: VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA K5305-1V5

1 80
Download 80 pages 15.84 Kb
Page 31
Image 31
*94 Download Phone Number

Data Field Programming

*93 No. of Reports In Armed Period per Zone (Swinger Suppression)

0 = unlimited number of reports

1 = 1 report pair per zone per armed period 2 = 2 report pairs per zone per armed period

Selection limits the number of alarm/alarm restore message pairs per zone sent to the CS in an armed period.

SIA Guidelines: Must be set for option 1 or 2.

V20PSIA/V15PSIA:

Report Pairs: 1 = 1 report pair; 2 = 2 report pairs

Unlimited Reports Enable:

0 = restrict reports to the setting in entry 1

1 = unlimited reports for zones listed in zone list 7;

(use zone list 7 to list zones that require unlimited reporting; these zones ignore the setting in entry 1)

*94 Download Phone Number

Enter up to 20 digits as follows: 0–9, # +11 for “”,

# + 12 for “#”, # + 13 for a pause.

Enter the phone number of the downloading computer. Do not fill unused spaces. End field by entering ∗. To clear entries from field, press ∗94∗.

*95 Ring Count For Downloading

0–15 = number of rings before control picks up phone line.

Refer to the chart below and program accordingly.

phone

answer

down-

Set field 95 to…

 

module

machine

loading

 

yes

no

no

1-14 (not 0)

 

 

yes

yes

no

higher

than

number of

 

 

 

rings

set

on

answer

 

 

 

machine (e.g.,

if ans.

 

 

 

machine is 4 rings, set

 

 

 

this field to 5). This allows

 

 

 

access

to

the

phone

 

 

 

module

if

the

answer

 

 

 

machine is off.

 

yes

no

yes

1-14 (not 0)

 

 

yes

yes

yes

15 (bypasses

answer

 

 

 

machine)

 

 

no

no

no

0

 

 

 

no

yes

no

0

 

 

 

no

no

yes

1-14

 

 

 

no

yes

yes

15

 

 

 

NOTE: If “15” is entered to bypass an answering machine, and a 4285 or 4286 Phone Module is included in the system, you should note the following:

When calling in from an off-premises phone, the user should make the initial call, allow 1 or 2 rings only, then hang up, then call again. The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible.

*96 Command to Initialize CSID and Subscriber Account Number

Use this command, if necessary, to reset all subscriber account numbers and the internal CSID to the factory default values.

*97 Command to Reset System to Factory Default Values

Pressing ∗97 resets all data fields to the factory default values (shown on the Program Form).

IMPORTANT: Do not press ∗97 to load defaults if any programming has been done previously—data already programmed into the system will be changed!

*98 Command to Exit Program Mode (with installer code lockout)

Exits Programming Mode and prevents re-entry by: Installer Code + [8] + [0] + [0].

To enter the programming mode if ∗ 98 was used to exit, you must first power down the system. Then power up again, and press [∗] and [#] at the same time, within 50 seconds of powering up. See field *88 for other Program mode lockout options.

*99 Command to Exit Program Mode

Exits Programming Mode and allows re-entry by: Installer Code + [ 8] + [0] + [0]

or by: Pressing [∗] and [#] at the same time, within 50 seconds of power-up.

Pager Programming Fields

The system can send various reports to several pagers (VISTA-20P = up to 4; VISTA-15P = up to 2).

To program pager reporting, do the following:

1.Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171:

2.Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).

3.Make sure appropriate user open/close pager reports are enabled (see Security Codes, Assigning Attributes in Section 6. System Communication and Operation). Users that perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 2.

4.If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then select event type 03). System must be armed for the Latchkey report to be sent.

5.If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key (function 01).

6.If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each pager (zone lists 9-12).

VISTA-20P supports four pagers and partitioning; VISTA-15P supports two pagers and zone lists 9 and 10 only.

*160 Pager 1 Phone No.

Enter up to 20 digits.

If entering fewer than 20 digits, exit by pressing [∗] + next field number. To clear entries, press ∗160∗.

4-7