Zone Number

Installation and Setup Guide

Enter Zn Num.

 

(00 = Quit)

10

Zone Number

VISTA-20P: wired 01-08 (and 09-48†); wireless 09-48; RF button zones 49-64

VISTA-15P: wired 01-06 (and 07-22†); wireless 09-34; RF button zones 49-56

Both Controls: 91 = addr. device report enable; 92 = duress report enable 95, 96, 99 =emerg. zones

[] to continue; 00 to quit

† if zone expanders are used.

Enter the zone number that you wish to program. Zone 10 has been entered in the example display at left.

Enter a report code for zone 91 to enable addressable device reporting. Enter a report code for zone 92 to enable duress reporting.

95, 96, 99 are emergency (panic) key zones.

 

 

 

 

 

Summary Screen

 

Zn ZT P RC

In: L

 

[] to continue

 

10 00

1 10

RF:

1

 

A summary display appears.

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

“IN: L” appears for wireless zones and indicates input type and loop.

 

Zn ZT P RC

In: AD

“IN: AD” appears for hardwire expansion zones (AW) and indicates the module’s address

 

10 00

1 10

AW: 07

(AD), which is based on the zone number.

 

OR

 

 

 

“HW: RT” appears for hardwire zones and indicates configuration (EOL, NO, NC, zone

 

Zn ZT P RC

HW: RT

doubling, double-balanced) and response time selection.

 

10 00

1 10

EL

1

 

 

 

 

 

 

 

 

 

 

 

 

 

10 Zone Type

Perimeter 03

Zone Type (ZT)

See table below.

Each zone must be assigned to a zone type, which defines the way in which the system responds to faults in that zone. Enter the Zone Type code from the list below:

Note: If 00 is entered, Delete Zone ? will be displayed.

00

= Not used

07

= 24-Hr Audible

20

= Arm–STAY*

01

= Entry/exit #1

08

= 24-Hr Aux

21

= Arm–AWAY*

02

= Entry/exit #2

09

= Fire

22

= Disarm*

03

= Perimeter

10

= Interior w/Delay

23

= No Alarm Resp

04

= Interior Follower

12 = Monitor Zone

24

= Silent Burglary

05

= Day/Night

14

= Carbon Monoxide

77

= Keyswitch

06

= 24-Hr Silent

16

= Fire w/Verify

81 = AAV Mon. Zone

*5800 button-type transmitters only

 

 

90-91 = Configurable

 

 

 

Partition No. (P) (VISTA-20P)

 

10 Partition

 

 

 

1-3 = partition (3 = common); [] to continue

 

 

1

 

 

Enter the Partition number for this zone. Partition 1 is shown entered.

 

 

 

 

 

 

 

 

 

Report Code (RC)

 

10 Report Code

 

First Digit: 1-9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F

 

1st 01 2nd 00 10

 

00 to disable

 

 

Second Digit: same as above; [] to continue

 

 

 

 

Enter the report code for this zone, which consists of 2 hexadecimal digits, each in turn

 

 

consisting of 2 numerical digits. For example, for a report code of “10,” enter 01 and 00.

 

 

For Contact ID®, entering any non-zero entry as the first digit enables the report code for

 

 

this zone. Refer to the System Communication section for information about report codes

 

 

and formats.

 

 

Hardwire Type

 

02 HARDWIRE TYPE

 

0 = EOL; 1 = NC; 2 = NO; 3 = zn doubling (ZD) †; 4 = dble-balanced (DB)

EOL

0

[] to continue

VISTA-20P

 

 

 

 

This prompt appears only for zone numbers 02-08.

Zone 1 is automatically set for EOL operation.

02 Response Time

1

Response Time (RT)

0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1.2 seconds; [] to continue

This prompt appears only for hard-wired zones 01-08 (zone 02 is the display shown). Option 3: used for “clean me” option on zone 1 (see field ∗174).

NOTE: If zone doubling is being used, the response time selected for zones 02-08 automatically applies to each zone’s associated doubled zone.

5-2