Honeywell K5305-1V5 Installation and Setup Guide, Auxiliary Device Current Draw Worksheet

Models: VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA K5305-1V5

1 80
Download 80 pages 15.84 Kb
Page 8
Image 8
Figure 3. Mounting the PC Board and RF Receiver

Installation and Setup Guide

CABINET

A

B

 

 

CABINET

 

 

BOARD

 

RECEIVER CIRCUIT BOARD

SUPPORTING

 

 

SLOTS

+

+

 

CIRCUIT

 

BOARD

 

MOUNTING

 

CLIP

CONTROL

CIRCUIT

BOARD

 

DETAIL A

MOUNTING

SIDE VIEW

CLIP

OF BOARD -

SUPPORTING SLOTS

INSTALLATION WITH RECEIVER CIRCUIT BOARD

WHITE

BLACK

RED

MOUNTING

MOUNTING

MOUNTING

CLIP

CLIP

CLIP

NOTE

A COMBINATION OF THESE MOUNTING CLIPS HAS BEEN INCLUDED IN YOUR INSTALLATION KIT.

USE THE APPROPRIATE CLIPS FOR MOUNTING.

IF NO RF RECEIVER IS USED, MOUNT THE PC BOARD USING EITHER THE WHITE OR BLACK CLIPS, WHICHEVER ARE INCLUDED IN THE CONTROL PANEL'S HARDWARE KIT.

ANTENNA

(2)

SCREW

(2) AUXILIARY DEVICE CURRENT DRAW WORKSHEET24-HOUR BATTERY BACKUP REQUIREMENTS

GROUNDING LUG Manual background

(2)

ANTENNA

MOUNT

(2 PLACES)

DETAIL B

ANTENNA AND GROUNDING

LUG INSTALLATION

pc_mount-001-V1

Figure 3. Mounting the PC Board and RF Receiver

AUXILIARY DEVICE CURRENT DRAW WORKSHEET

 

DEVICE

CURRENT

No. UNITS

TOTAL CURRENT

6150

Fixed-Word Keypad

40mA/70mA**

 

 

6160

Alpha Keypad

40mA/150mA**

 

 

6150V Fixed-Word Display Voice Keypad

60mA/160mA**

 

 

6160V Alpha Display Voice Keypad

60mA/190mA**

 

 

8132/8142 Series AUI (Symphony)

150mA/400mA**

 

 

6270

Touch Screen Keypad

180mA/280mA**

 

 

5881/5882 RF Receiver

60mA

 

 

5883

Transceiver

80mA

 

 

4219 Zone Expander

30mA

 

 

4204

Relay Unit

15/180mA

 

 

4229

Zone Expander/Relay Unit

30/100mA

 

 

4285 Phone Module

160mA

 

 

4286 Phone Module

300mA

 

 

 

 

 

 

 

*

 

 

 

 

(Current available from Aux. terminals = 600

mA max.)

TOTAL =

 

*If using hardwire devices such as PIRs, refer to the specifications for that particular unit's current draw. ** Values are for standby/alarm; alarm for keypads means armed with backlighting on and sounder on

†In UL installations, maximum current draw from the Auxiliary Output and the Alarm Output combined must not exceed 600 mA (500 mA max from Aux. Output). ‡Values are for relays OFF/relays ON.

CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE

24-HOUR BATTERY BACKUP REQUIREMENTS

The California State Fire Marshal and UL have regulations which require that all residential fire alarm control panels must be provided with a backup battery which has sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition. This control panel can meet these requirements without using a supplementary power supply, provided that the panel’s auxiliary power and bell output currents are limited as indicated below.

OUTPUT LIMITATIONS AND CORRESPONDING REQUIRED BATTERIES

OUTPUT CURRENT LIMITATIONS

BATTERY INFORMATION

Output Current Total

Maximum Auxiliary Current

Battery Capacity

Recommended Battery

 

 

To Use (Amp/Hrs)

(Yuasa Model No.)

600mA maximum total of

45mA

4AH

NP4-12 (or ADEMCO 467)

auxiliary power plus bell

160mA

7AH

NP7-12

output currents

200mA

8AH

NP4-12 (two) ‡

 

425mA

14AH

NP7-12 (two) ‡

 

500mA

17.2AH

NPG18-12

NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will fit inside the cabinet.)

2-2

Page 8
Image 8
Honeywell K5305-1V5 Installation and Setup Guide, Auxiliary Device Current Draw Worksheet, Hourbattery Backup Requirements