Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Programming Overview, Type, Alarm

Models: VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA K5305-1V5

1 80
Download 80 pages 15.84 Kb
Page 23
Image 23
Programming Overview

 

 

Programming Overview

 

 

 

 

Type 05

• Assign to a zone that contains a foil-protected door or window (such as in a store), or to a zone

 

Trouble by Day/

covering a sensitive area such as a stock room, drug supply room, etc.

 

Alarm by Night

• Can also be used on a sensor or contact in an area where immediate notification of an entry is

 

 

desired.

 

 

• Provides an instant alarm if faulted when armed in the Away, Stay, Night-Stay, Instant or

 

 

Maximum (night) modes.

 

 

• During the disarmed state (day), the system will provide a latched trouble sounding from the

 

 

keypad (and a central station report, if desired).

 

Type 06

• Usually assigned to a zone containing an emergency button.

 

24-hr Silent Alarm

• Sends a report to the central station but provides no keypad display or sounding.

 

 

 

 

Type 07

• Assign to a zone that has an emergency button.

 

24-hour Audible

• Sends a report to the central station, and provides an alarm sound at the keypad, and an

 

Alarm

audible external alarm.

 

 

 

 

Type 08

• Assign to a zone containing an emergency button, or to a zone containing monitoring devices

 

24-hour

such as water or temperature sensors.

 

Auxiliary Alarm

• Sends a report to the central station and provides an alarm sound at the keypad. (No bell

 

 

output is provided.)

 

Type 09

• Provides a fire alarm on short circuit and a trouble condition on open circuit. A fire alarm

 

Supervised Fire

produces a pulsing bell output.

 

 

• This zone type is always active and cannot be bypassed.

 

 

 

 

Type 10

• Provides entry delay (using the programmed entry time), if tripped when the panel is armed in

 

Interior w/Delay

the Away mode.

 

 

• Entry Delay 1 begins whenever sensors in this zone are violated, regardless of whether or not

 

 

an entry/exit delay zone was tripped first.

 

 

• Bypassed when the panel is armed in the Stay or Instant modes; if armed in Night-Stay mode,

 

 

zones assigned to zone list 05 (night-stay zone list) are not bypassed when system armed in

 

 

Night-Stay mode.

 

Type 12

• Works as a dynamic monitor of a zone fault/trouble (not alarm). In the case of a short/open, the

 

Monitor Zone

message, "*ALARM*-24 Hr. Non-Burg. -#XXX " (where XXX is the zone number) will be sent

 

 

to the Central Station. The system keypad will display a “check” message indicating the

 

 

appropriate zone (but keypad beeping does not occur). Upon restoral of the zone, the message,

 

 

"*RESTORE*-24 Hr. Non-Burg. -#XXX " will be sent to the Central Station.

 

 

• The “check” message will automatically disappear from the keypad dynamically, when the

 

 

zone restores; a user code + off sequence is not needed to reset the zone.

 

 

• Faults of this zone type are independent of the system, and can exist at the time of arming

 

 

without interference.

 

 

• Since this is a “trouble” zone type, do not use this zone type with relays set to activate upon

 

 

“alarm.”

 

Type 14

• Assigned to any zone with a carbon monoxide detector.

 

24 Hour Carbon

• The bell output will pulse when this zone type is alarmed.

 

Monoxide

• Always active and cannot be bypassed.

 

Monitor

 

 

Type 16

• Provides a fire alarm when zone is shorted, but only after alarm verified.

 

Fire

• System verifies alarm by resetting zones for 12 seconds after short is detected. A subsequent

 

w/Verification

short circuit within 90 seconds triggers fire alarm.

 

 

• Provides a trouble response when zone is open.

 

Type 20

• Arms the system in Stay mode when the zone is activated.

 

Arm-Stay (BR

• Pushbutton units send the user number to the central station when arming or disarming.

 

only)

• User number for button must be assigned.

 

 

 

 

Type 21

• Arms the system in Away mode when the zone is activated.

 

Arm-Away (BR

• Pushbutton units send the user number to the central station when arming or disarming.

 

only)

• User number for button must be assigned.

 

 

 

 

Type 22

• Disarms the system when the zone is activated.

 

Disarm (BR only)

• User number for button must be assigned.

 

 

 

3-3

Page 23
Image 23
Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Programming Overview, Type, Trouble by Day, Alarm by Night