Installation and Setup Guide

Compatible 5800 Series Transmitters Table (continued)

Model

Product

Input Type

Description

5817

Multi-Point Universal

RF

Has three unique input (loop) codes: one for a “Primary” contact

 

Transmitter

 

loop with programmable options; the others for two “auxiliary”

 

 

 

closed circuit contact loops.

5818

Recessed Transmitter

RF

Reed switch magnetic contact sensor; easily hidden in the frame

 

 

 

and edge of a door or window.

 

 

 

Has a single unique input (loop) code.

5819

Shock Processor

RF

Connects to externally mounted inertia-type shock detector (not

 

Transmitter

 

supplied).

 

 

 

Has built-in tampered cover switch.

 

 

 

Has 3 unique input (loop) codes:

 

 

 

Loop 1: Terminals for a wired, N.C. sensor loop.

 

 

 

Loop 2: For a closed circuit contact loop using the built-in reed

 

 

 

switch in conjunction with a magnet.

 

 

 

Loop 3: Terminals for a wired, closed circuit contact loop.

5819WHS

Shock Processor

RF

Has built-in shock sensor.

5819BRS

Transmitter

 

Has built-in tampered cover switch.

 

 

 

Has 3 unique input (loop) codes:

 

 

 

Loop 1: Built-in shock sensor loop wired to TB1 (normally closed).

 

 

 

Loop 2: For a closed circuit contact loop using the built-in reed

 

 

 

switch in conjunction with a magnet.

 

 

 

Loop 3: Externally wired, closed circuit loop connected to TB2.

5827

Wireless Keypad

Uses House

Can be used to turn the burglary protection on and off.

 

 

ID only

Features the same built-in panic functions as wired keypads.

 

 

 

The keypad is identified as zone “00” on wired keypads when it

 

 

 

transmits with a low battery.

5827BD

Wireless Two-Way

Uses House

Requires 5800TM Transmitter Module.

 

Keypad

ID only

Operates the system similarly to wired keypads, including panics.

 

 

 

Can indicate system status via its 3 LEDs and sounder.

 

 

 

Includes 3 panic keys.

5849

Glassbreak Detector

RF

House ID must also be set.

 

 

 

Requires both sound and shock of breaking glass to cause alarm

 

 

 

to be transmitted.

5890

PR Detector

RF

Dual-element passive infrared detector/transmitter with built-in

 

 

 

selectable pulse count.

 

 

 

Note: There is a 3-minute lockout between fault transmissions to

 

 

 

conserve battery life.

5899

Magnets

 

Package of 4 magnets for use with 5816 and 5817 transmitters.

8-4

Page 68
Image 68