Installation and Setup Guide

SUMMARY OF ARMING MODES

Arming Mode

 

Features for Each Arming Mode

 

 

Exit Delay

Entry Delay

Perimeter Armed

Interior Armed

AWAY

Yes

Yes

Yes

Yes

 

 

 

 

 

STAY

Yes

Yes

Yes

No

NIGHT-STAY

Yes

Yes

Yes

only those zones

 

 

 

 

listed in Night-

 

 

 

 

Stay zone list

INSTANT

Yes

No

Yes

No

 

 

 

 

 

MAXIMUM

Yes

No

Yes

Yes

Panic Keys

There are three Panic keys (A, B, and C) that, if programmed, can be used to manually initiate alarms and send a report to the central station.

Each key can be programmed for 24-hour Silent, 24-hour Audible, Fire, or Personal Emergency responses. The programmed Panic response is activated when the appropriate key is pressed for at least 2 seconds.

The Panic keys are identified by the system as follows:

Keys

Displayed as Zone

[A] (/1)

95

[B] (/#)

99

[C] (3/#)

96

IMPORTANT: For a Silent panic function (if programmed) to be of practical value, you must program a report code for the zone and the system must be connected to a central station.

Setting the Real-Time Clock

Set the time and date by doing the following:

1. +[#] + [6] [3]

(Security Code)

2.Press [∗] when the time/date is displayed.

A cursor appears under the first digit of the hour. To move cursor ahead, press []. To go back, press [#].

Enter the 2-digit hour setting.

Enter the 2-digit minute setting.

Press [1] for PM or [2] for AM.

Enter the last two digits of the current year.

Enter the 2-digit month setting.

Enter the 2-digit day setting.

3.To exit, press [∗] when cursor is at the last digit, or wait 10 seconds.

Alpha Display:

DISARMED

READY TO ARM

TIME/DATE SAT 04:04PM 10/17/00

Current time display

TIME/DATE SAT 04:04P2000/10/17

Time/date editing display

6-6

Page 60
Image 60
Honeywell K5305-1V5 setup guide Setting the Real-Time Clock, Keys Displayed as Zone ∗ /1 ∗ /#